OPERATION n Press Bluetooth® pairing button to turn the LCD display on. NOTE: The LCD display must be on for the engine to be started with the start button. n Press and hold the start button for 5 seconds to start the engine. If the engine does not start, press and hold the start button again. n The generator can also be started by pulling the recoil starter grip until the engine runs. This method can start the engine with or without the battery pack installed. NOTE: Do not allow the grip to snap back after starting; return it gently to its original place. The generator can also be started with the GENCONTROL™ app. The app must be paired and within connection range for the electric start function to work. If you can't pair and the display is off, verify the EASY START dial is in the ON position, then press and release the Bluetooth® pairing button and try to pair again. Sleep mode: n After 30 minutes of maximum inactivity, the product will enter into sleep mode. In this state, the LED will turn off. The Bluetooth® connection will remain active in this mode to allow remote wake up. All other functions are disabled during this time. GenControl Automatic shut-off: n GenControl will automatically power off after 12 hours of inactivity in Sleep Mode. The Bluetooth® connection is also disabled at this time To manually turn the product off: n Turn the start dial to the OFF position. n Always turn the start dial to the OFF position when generator is not in use. STOPPING THE ENGINE See Figure 6. n Remove any load from the generator. n Place the EASY START dial in the OFF/STORAGE position. To stop the engine in an emergency situation: n Place the EASY START dial in the OFF/STORAGE position. WARNING: While operating and storing, keep at least 3 feet of clearance on all sides of this product, including overhead. Allow a minimum of 30 minutes of "cool down" time before storage. Heat created by muffler and exhaust gases could be hot enough to cause serious burns and/ or ignite combustible objects. ADJUSTING THE CHOKE MANUALLY See Figure 8. If the generator does not start when the EASY START dial is in the ON position or if the engine lacks power during operation, you may need to manually adjust the choke by following the instructions below. If the engine will not start using the EASY START dial: n Unplug all loads from the generator. n Loosen the knob at the side of the engine cover. Remove cover and set aside. n Move the choke to the closed position. n Reinstall cover. If the engine lacks power during operation: n Unplug all loads from the generator. n Loosen the knob at the side of the engine cover. Remove cover and set aside. n Move the choke to the open position. n Reinstall cover. PAIRING THE BLUETOOTH® GENERATOR See Figure 9. Installing the RYOBI™ GENCONTROL™ app on your Bluetooth® enabled iOS or Android device allows you to view and control many of the generator's functions from your device.  From the app store on your iOS or Android Bluetooth® enabled device, locate and install the RYOBI™ GENCONTROL™ app.  Open the app and follow the directions as shown in the GENCONTROL™ app. NOTE: Make sure Bluetooth® is enabled on your device.  Make sure the EASY START DIAL is in the ON position. Push and hold the Bluetooth pairing button below the LCD panel on the generator until the LCD panel displays "Pairing Mode."  The LCD screen on the generator and the app on your device will indicate a successful pairing. NOTE: If the generator and app do not pair, make sure that "Pairing Mode" is displayed during the pairing process and that Bluetooth® is enabled on your device.  Press the menu icon in the top left corner of the screen. This will show you the available features that can be controlled through the app. 17 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

17 — English
OPERATION
Press
Bluetooth
®
pairing button to turn the LCD display
on.
NOTE:
The LCD display must be on for the engine to be
started with the start button.
Press and hold the start button for 5 seconds to start the
engine. If the engine does not start, press and hold the
start button again.
The generator can also be started by pulling the recoil
starter grip until the engine runs. This method can start
the engine with or without the battery pack installed.
NOTE:
Do not allow the grip to snap back after starting;
return it gently to its original place.
The generator can also be started with the GENCONTROL
app. The app must be paired and within connection range
for the electric start function to work. If you can’t pair and
the display is off, verify the EASY START dial is in the ON
position, then press and release the
Bluetooth
®
pairing button
and try to pair again.
Sleep mode:
After 30 minutes of maximum inactivity, the product will
enter into sleep mode. In this state, the LED will turn off.
The
Bluetooth
®
connection will remain active in this mode
to allow remote wake up. All other functions are disabled
during this time.
GenControl Automatic shut-off:
GenControl will automatically power off after 12 hours of
inactivity in Sleep Mode. The
Bluetooth®
connection is
also disabled at this time
To manually turn the product off:
Turn the start dial to the OFF position.
Always turn the start dial to the OFF position when
generator is not in use.
STOPPING THE ENGINE
See Figure 6.
Remove any load from the generator.
Place the EASY START dial in the OFF/STORAGE position.
To stop the engine in an emergency situation:
Place the EASY START dial in the OFF/STORAGE position.
WARNING:
While operating and storing, keep at least 3 feet of
clearance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of “cool down” time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
ADJUSTING THE CHOKE MANUALLY
See Figure 8.
If the generator does not start when the EASY START dial
is in the ON position or if the engine lacks power during
operation, you may need to manually adjust the choke by
following the instructions below.
If the engine will not start using the EASY START dial:
Unplug all loads from the generator.
Loosen the knob at the side of the engine cover. Remove
cover and set aside.
Move the choke to the closed position.
Reinstall cover.
If the engine lacks power during operation:
Unplug all loads from the generator.
Loosen the knob at the side of the engine cover. Remove
cover and set aside.
Move the choke to the open position.
Reinstall cover.
PAIRING THE BLUETOOTH
®
GENERATOR
See Figure 9.
Installing the RYOBI
GENCONTROL
app on your
Bluetooth
®
enabled iOS or Android device allows you to
view and control many of the generator’s functions from
your device.
From the app store on your iOS or Android
Bluetooth
®
enabled device, locate and install the RYOBI
GENCONTROL
app.
Open the app and follow the directions as shown in the
GENCONTROL
app.
NOTE:
Make sure
Bluetooth
®
is enabled on your device.
Make sure the EASY START DIAL is in the ON position.
Push and hold the Bluetooth pairing button below the
LCD panel on the generator until the LCD panel displays
"Pairing Mode."
The LCD screen on the generator and the app on your
device will indicate a successful pairing.
NOTE:
If the generator and app do not pair, make sure
that “Pairing Mode” is displayed during the pairing process
and that
Bluetooth
®
is enabled on your device.
Press the menu icon in the top left corner of the screen.
This will show you the available features that can be
controlled through the app.