Seagate ST800FM0022 Pulsar.2 SAS Product Manual - Page 33

GB models in 6Gb operation, 400GB models in 6Gb operation, 200GB models in 6Gb operation

Page 33 highlights

6.4 POWER DISSIPATION 800GB models in 6Gb operation Typical power dissipation under idle conditions in 6Gb operation is 4.38 watts 14.95 BTUs per hour). To obtain operating power for typical random write operations, refer to the following I/O rate curve (see Figure 6). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123. Figure 5. 800GB (at 6Gb) DC current and power vs. input/output operations per second 400GB models in 6Gb operation Typical power dissipation under idle conditions in 6Gb operation is 3.49 watts 11.91 BTUs per hour). To obtain operating power for typical random write operations, refer to the following I/O rate curve (see Figure 6). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123. Figure 6. 400GB (at 6Gb) DC current and power vs. input/output operations per second 200GB models in 6Gb operation Typical power dissipation under idle conditions in 6Gb operation is 3.47 watts (11.84 BTUs per hour). PULSAR.2 SAS PRODUCT MANUAL, REV. C 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

P
ULSAR
.2 SAS P
RODUCT
M
ANUAL
, R
EV
. C
27
6.4
P
OWER DISSIPATION
800GB models in 6Gb operation
Typical power dissipation under idle conditions in 6Gb operation is 4.38 watts 14.95 BTUs per hour).
To obtain operating power for typical random write operations, refer to the following I/O rate curve (see Figure 6). Locate the typical I/O rate
for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical
axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 5.
800GB (at 6Gb) DC current and power vs. input/output operations per second
400GB models in 6Gb operation
Typical power dissipation under idle conditions in 6Gb operation is 3.49 watts 11.91 BTUs per hour).
To obtain operating power for typical random write operations, refer to the following I/O rate curve (see Figure 6). Locate the typical I/O rate
for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical
axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 6.
400GB (at 6Gb) DC current and power vs. input/output operations per second
200GB models in 6Gb operation
Typical power dissipation under idle conditions in 6Gb operation is 3.47 watts (11.84 BTUs
per hour).