Sharp AR-RB1 Service Manual - Page 5
Connect the harness of the duplex bypass, inverter unit.
View all Sharp AR-RB1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
3) Attach the transport guide to the duplex bypass/inverter unit and insert the two transport guide holders into the two transport guides respectively. At this time, ensure that the transport guide holders are secured at the notch positions. 4) After checking that the transport guide is aligned with the guide of the stand, close the left cover of the main unit securely. 3) Connect the relay harness of the duplex bypass/inverter unit to the connector of the optional stand. Then, insert the snap band into the mounting hole shown in the illustration to secure the relay harness. Connector Rear side Snap band Front side Transport guide holders Front side Rear side Notch Transport guide Notch Transport guide Transport guide holder Notches Transport guide holder 7. Connect the harness of the duplex bypass/ inverter unit. 1) Remove the screw from the power supply cover on the rear side of the optional stand and then remove the power supply cover. Relay harness 4) Pass the relay harness through the cut out hole, hang the two pawls of the power supply cover on the rear cabinet, and attach the cover with the screw. Installation of AR-RB1 is now complete. Screw Pawls Power supply cover Relay harness Power supply cover Screw 2) Cut out the portion (indicated with H) of the removed power supply cover shown in the illustration. Cut-out portion AR-RB1 UNPACKING AND INSTALLATION 2 - 4