Sharp ER-A320 Programmer Manual - Page 15

Programming by JOB# entry - programing

Page 15 highlights

2. Programming by JOB# entry [JOB#1110] PROGRAMMING OF DEPT. PRICE 1110 No change @/FOR XX @/FOR DEPT. CODE YYYYYYY price #/TM/ SBTL For the next DEPT. CA/AT XX : DEPT- CODE = 01 ~ 40max YYYYYYY : PRICE = 0 ~ 9999999 Preset price is max. 7 digits. Price can be programmed for each dept. If this programming is perfomed, the ECR is automatically programmed to allow preset price entry even when it has been programmed not to allow preset price entry in dept. function programmng (JOB#2110). MRS = 0000000 [JOB#2110] PROGRAMMING OF DEPT. FUNCTlON 2110 No change @/FOR XX @/FOR DEPT. CODE ABCD For next code CL #/TM/ SBTL CA/AT XX : DEPT. code = 01 ~ 40 max. A : ltem validation printing A Non compulsory 0 Compulsory 1 B : SICS Function B Normal 0 Single item cash sale 1 C : Dept. type C Normal 0 HASH 1 D : AmDunt entry type D Inhibited 0 Open 1 Preset 2 Open and preset 3 MRS = 0001 [JOB#2111] DEPT. TAX STATUS AND SIGN PROGRAMMING 2111 No change @/FOR XX @/FOR DEPT. CODE ABCDEF #/TM/ SBTL For the next DEPT. CL CA/AT XX : DEPT. CODE = 01 ~ 40max. A : Sign A + 0 - 1 B : Not used (Fixed at "0") C : Taxable 4 C Non taxable 0 Taxable 1 D : Taxable 3 D Non taxable 0 Taxable 1 E : Taxable 2 E Non taxable 0 Taxable 1 F : Taxable 1 F Non taxable 0 Taxable 1 MRS = 000000 [JOB#2112] DEPT. HALO (limit) preset 2112 No change @/FOR XX @/FOR AB DEPT. CODE #/TM/ SBTL For the next DEPT. CL CA/AT XX : DEPT. CODE = 01 ~ 40max. A : Mantissa(HALO) = 1 ~ 9 B : Exponent (HALO) = 0 ~ 7 Items A and B indicate A x 10B . Any amount below that value is enable within 9999999. MRS = 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

2.
Programming by JOB# entry
[JOB#1110]
PROGRAMMING OF DEPT. PRICE
XX : DEPT- CODE = 01 ~ 40max
YYYYYYY : PRICE = 0 ~ 9999999
Preset price is max. 7 digits.
Price can be programmed for each dept. If this programming is perfo-
med, the ECR is automatically programmed to allow preset price entry
even when it has been programmed not to allow preset price entry in
dept. function programmng (JOB#2110).
MRS = 0000000
[JOB#2110]
PROGRAMMING OF DEPT. FUNCTlON
XX :
DEPT. code = 01 ~ 40 max.
A :
ltem validation printing
A
Non compulsory
0
Compulsory
1
B :
SICS Function
B
Normal
0
Single item cash sale
1
C :
Dept. type
C
Normal
0
HASH
1
D :
AmDunt entry type
D
Inhibited
0
Open
1
Preset
2
Open and preset
3
MRS = 0001
[JOB#2111]
DEPT. TAX STATUS AND SIGN PROGRAMMING
XX :
DEPT. CODE = 01 ~ 40max.
A :
Sign
A
+
0
1
B : Not used (Fixed at "0")
C :
Taxable 4
C
Non taxable
0
Taxable
1
D :
Taxable 3
D
Non taxable
0
Taxable
1
E :
Taxable 2
E
Non taxable
0
Taxable
1
F :
Taxable 1
F
Non taxable
0
Taxable
1
MRS = 000000
[JOB#2112]
DEPT. HALO (limit) preset
XX :
DEPT. CODE = 01 ~ 40max.
A :
Mantissa(HALO) = 1 ~ 9
B :
Exponent (HALO) = 0 ~ 7
Items A and B indicate A x 10
B
. Any amount below that value
is enable within 9999999.
MRS = 17
No change
#/TM/
SBTL
1110
YYYYYYY
@/FOR
@/FOR
CA/AT
XX
price
DEPT. CODE
For the next DEPT.
2110
ABCD
@/FOR
@/FOR
CA/AT
XX
DEPT. CODE
For next code
No change
CL
#/TM/
SBTL
2111
ABCDEF
@/FOR
@/FOR
CA/AT
XX
DEPT. CODE
For the next DEPT.
No change
CL
#/TM/
SBTL
2112
AB
@/FOR
@/FOR
CA/AT
XX
DEPT. CODE
For the next DEPT.
No change
CL
#/TM/
SBTL