Sharp ER-A330 Installation Manual - Page 7

Drawer Fixing Kit, Dkit-8633rczz - cash drawer

Page 7 highlights

3. Installation procedure for ER-A330 1) Remove the top cabinet. 2) Remove the main PWB. 3) Solder the drawer connector CN16, the resistor (1kΩ) R89, and the transistor (2SC3784) Q20 to the main PWB. 4) Replace the main PWB. 5) Connect the drawer cable to the drawer connector on the main PWB. 6) Use nippers to cut off drawer cable binding holder  on the bottom cabinet, and bind drawer cable of the ER-04DW. Screw ! used in this case is an accessory of the ER-04DW. 7) Use nippers to cot off the drawer cable split pin of the top cabinet, and attach the top cabinet. 3 1 2 8) Fix ground wire " of the ER-04DW on the standard drawer with screw #. Screw # used in this case is an accessory of the ER-04DW. 4. Operation test CHAPTER 8. DRAWER FIXING KIT (DKIT-8633RCZZ) The drawer fixing kit is used for securing the cash drawer when installing separately from the ECR main unit or remote drawer. By using two of brackets, the drawer box can be protected from 5 drifting especially when it is filled with coins. 4 CN16 1. Parts list KIT CODE: DKIT-8633RCZZ Main PWB. No. Parts code Description Q'ty 1 LBRC–2321RCZZ Fixing bracket 2 2 XTPSD40P16000 Tapping screw M4x16 4 3 XBSSD40P16000 Flat head screw M4x16 (For remote drawer) 2 4 XUSSD40P20000 Flat head screw M4x20 (For standard drawer) 2 5 XBPSD40P22000 Screw M4x22 4 6 XNESD40–32000 NUT M4x32 4 – 6 –

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

3. Installation procedure for ER-A330
1)
Remove the top cabinet.
2)
Remove the main PWB.
3) Solder the drawer connector CN16, the resistor (1k
) R89, and
the transistor (2SC3784) Q20 to the main PWB.
4)
Replace the main PWB.
5) Connect the drawer cable to the drawer connector on the main
PWB.
6)
Use nippers to cut off drawer cable binding holder on the bottom
cabinet, and bind drawer cable of the ER-04DW.
Screw used in this case is an accessory of the ER-04DW.
7)
Use nippers to cot off the drawer cable split pin of the top cabinet,
and attach the top cabinet.
8) Fix ground wire of the ER-04DW on the standard drawer with
screw .
Screw used in this case is an accessory of the ER-04DW.
4. Operation test
CHAPTER 8.
DRAWER FIXING KIT
(DKIT–8633RCZZ)
The drawer fixing kit is used for securing the cash drawer when in-
stalling separately from the ECR main unit or remote drawer.
By using two of brackets, the drawer box can be protected from
drifting especially when it is filled with coins.
1. Parts list
KIT CODE: DKIT–8633RCZZ
No.
Parts code
Description
Q’ty
1
Fixing bracket
2
2
Tapping screw M4x16
4
3
Flat head screw M4x16
(For remote drawer)
2
4
Flat head screw M4x20
(For standard drawer)
2
5
Screw M4x22
4
6
NUT M4x32
4
4
5
CN16
Main PWB.
1
3
2