Sharp PG-C20XU PG-C20XU Operation Manual - Page 42
Resetting the lamp timer
View all Sharp PG-C20XU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Replacing the Projection Lamp 7 Remove the lamp cage cover. Turn over the projector and loosen the user service screw that secures the lamp cage cover. Then lift open the cover in the direction of the arrow. 8 Remove the lamp cage. Loosen the securing screws on the lamp cage. Hold the lamp cage by the handle and pull it towards you. 9 Insert the new lamp cage. Press the lamp cage firmly into the lamp cage compartment. Fasten the securing screws. 10 Attach the lamp cage cover. Slide the lamp cage cover in the direction of the arrow. Then tighten the user service screw. Maintenance & Troubleshooting Resetting the lamp timer 1 Connect the power cord. Plug the power cord into the AC socket of the projector. 2 Reset the lamp timer. 1 Press KEYSTONE ∂ and KEYSTONE ƒ on the projector at the same time. 2 Press INPUT and AUTO SYNC on the projector at the same time. 3 Press AUTO SYNC and MENU on the projector at the same time. 2 1 INPUT AUTO SYNC BACK ENTER MENU 3 "LAMP 0000H" is displayed, indicating that the lamp timer is reset. • Reset the lamp timer only after replacing the lamp. E-41