Sharp R930AK Service Manual - Page 11

Schematic Diagram

Page 11 highlights

IMPORTANT: During sensor cooking operation, the fire sensing operation sequence will not begin until the AH sensor has R-930AK R-930AW detected vapors and initiated a sensor cooking cycle. This is because the operation of the convection fan would interfere with the AH sensor's vapor detection. H.V. RECTIFIER MAGNETRON SCHEMATIC DIAGRAM SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED. 2. CLOCK APPEARS ON DISPLAY. CONV. THERMAL CUT-OUT MAGNETRON TEMPERATURE FUSE MONITOR SWITCH FUSE OUTER CASE SWITCH TTM OL FM CM DM TURNTABLE MOTOR OVEN LAMP FAN MOTOR CONVECTION MOTOR DAMPER MOTOR 120V 60Hz OUTER CASE SWITCH SECONDARY INTERLOCK SWITCH A-1 A-3 A-5 COM. (RY1) RY4 RY5 RY6 RY1 A-7 A-9 CONTROL UNIT F-1 F-2 F-3 N.O. (RY1) COM. (RY3) RY2 RY2 COM. PRIMARY (RY2) RY3 INTERLOCK RERAY N.O. (RY2) E-1 E-2 E-3 E-4 E-5 E-6 N.O. (RY3) AH SENSOR DOOR SENSING SWITCH THER- DAMPER MISTOR SWITCH HEATIMG ELEMENT SCHEMATIC 1. DOOR CLOSED. 2. COOKING TIME PROGRAMMED. 3. "START" PAD TOUCHED. Figure O-1. Oven Schematic-OFF Condition CONV. THERMAL CUT-OUT MAGNETRON TEMPERATURE FUSE MONITOR SWITCH FUSE OUTER CASE SWITCH TTM OL FM CM DM TURNTABLE MOTOR OVEN LAMP FAN MOTOR CONVECTION MOTOR DAMPER MOTOR 120V 60Hz OUTER CASE SWITCH SECONDARY INTERLOCK SWITCH A-1 A-3 A-5 COM. (RY1) RY4 RY5 RY6 RY1 A-7 A-9 CONTROL UNIT F-1 F-2 F-3 N.O. (RY1) COM. (RY3) RY2 RY2 COM. PRIMARY (RY2) RY3 INTERLOCK RERAY N.O. (RY2) E-1 E-2 E-3 E-4 E-5 E-6 N.O. (RY3) AH SENSOR DOOR SENSING SWITCH THER- DAMPER MISTOR SWITCH HEATIMG ELEMENT Figure O-2. Oven Schematic-Microwave Cooking Condition 9 POWER TRANSFORMER CAPACITOR 0.94µ POWER TRANSFORMER CAPACITOR 0.94µ H.V. RECTIFIER MAGNETRON

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

9
R-930AK
R-930AW
Figure O-2. Oven Schematic-Microwave Cooking Condition
IMPORTANT:
During sensor cooking operation, the fire sensing op-
eration sequence will not begin until the AH sensor has
SCHEMATIC
1.
DOOR CLOSED.
2.
COOKING TIME PROGRAMMED.
3.
“START” PAD TOUCHED.
Figure O-1. Oven Schematic-OFF Condition
SCHEMATIC
NOTE: CONDITION OF OVEN
1.
DOOR CLOSED.
2.
CLOCK APPEARS ON DISPLAY.
detected vapors and initiated a sensor cooking cycle.
This is because the operation of the convection fan
would interfere with the AH sensor's vapor detection.
SCHEMATIC DIAGRAM
CONV.
THERMAL
CUT-OUT
MONITOR SWITCH
OVEN LAMP
FAN MOTOR
A-5
A-3
A-1
E-6
CONTROL UNIT
DAMPER
SWITCH
THER-
MISTOR
DOOR
SENSING
SWITCH
AH SENSOR
DAMPER MOTOR
CONVECTION MOTOR
TURNTABLE MOTOR
HEATIMG ELEMENT
MAGNETRON
POWER
TRANSFORMER
H.V. RECTIFIER
CAPACITOR
0.94
μ
RY4
RY5
RY6
RY1
SECONDARY
INTERLOCK
SWITCH
OUTER
CASE
SWITCH
OUTER
CASE
SWITCH
120V
60Hz
TTM
FM
COM.
(RY1)
E-5
E-4
E-3
E-2
E-1
F-3
F-2
F-1
RY3
RY2
PRIMARY
INTERLOCK
RERAY
N.O.
(RY1)
COM.
(RY3)
COM.
(RY2)
N.O.
(RY2)
N.O.
(RY3)
A-9
A-7
CM
DM
OL
MAGNETRON
TEMPERATURE
FUSE
FUSE
RY2
CONV.
THERMAL
CUT-OUT
MONITOR SWITCH
OVEN LAMP
FAN MOTOR
A-5
A-3
A-1
E-6
CONTROL UNIT
DAMPER
SWITCH
THER-
MISTOR
DOOR
SENSING
SWITCH
AH SENSOR
DAMPER MOTOR
CONVECTION MOTOR
TURNTABLE MOTOR
HEATIMG ELEMENT
MAGNETRON
POWER
TRANSFORMER
H.V. RECTIFIER
CAPACITOR
0.94
μ
RY4
RY5
RY6
RY1
SECONDARY
INTERLOCK
SWITCH
OUTER
CASE
SWITCH
OUTER
CASE
SWITCH
120V
60Hz
TTM
FM
COM.
(RY1)
E-5
E-4
E-3
E-2
E-1
F-3
F-2
F-1
RY3
RY2
PRIMARY
INTERLOCK
RERAY
N.O.
(RY1)
COM.
(RY3)
COM.
(RY2)
N.O.
(RY2)
N.O.
(RY3)
A-9
A-7
CM
DM
OL
MAGNETRON
TEMPERATURE
FUSE
FUSE
RY2