Sony EVID90 User Manual (EVI-D80/D90 User Manual) - Page 19
Effect, Power Off, Command, Initializing, During displaying, the menu, Memory Recall
![]() |
View all Sony EVID90 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Effect Mode Command CAM_Aperture Reset/Up/Down/Direct Display info. (ON/OFF) CAM_PictureEffect OFF/Neg.Art/B&W CAM_ICR ON/OFF CAM_AutoICR ON/OFF/Threshold CAM_HR ON/OFF CAM_NR Power Off1) No No No No No No No IFC2) No No No No No No No Power On Initializing3) During displaying the menu No Yes4) No Yes4) No Yes4) No Yes4) No Yes4) No Yes4) No Yes4) Memory Recall No No No No No No No 1) DC power is being supplied, but the camera has been turned off by a VISCA command. 2) The period from the time IF Clear is sent, until the Reply Packet is returned. 3) The period from the time DC power is turned on or the camera is turned on via a VISCA command, and the camera subsequently finishes the pan/tilt reset operation and stops at the Home position, until the video signal is output. Or the period from the time the CAM Power ON command is sent, until Completion is returned. 4) When the menu display is updating, operation is not possible. Basic Functions 19