http://www.xiaoyu163.com HCD-DH3/DH5BT/DH7BT TEL 13942296513 QQ 376315150 892498299 TEL 13942296513 QQ 376315150 892498299 QQ 376315150 DVD SECTION 1. DVD SERVICE MODE GENERAL DESCRIPTION This mode let you make diagnosis and adjustment easily by using the remote commander and the TV screen. The instructions, diagnostic results, etc. are given on the on-screen display. 2. ENTERING DVD SERVICE MODE Procedure: 1. Press the I/1 button to turn on the system. 2. Press the DVD N button to select the "DVD". 3. Press three buttons of x , [VOLUME +] and [PROGRESSIVE] simultaneously. 4. The message "SERVICE IN" appears on the fluorescent indicator tube and top menu of the Remocon Diagnosis Menu appears on the on-screen display on the TV screen as follows. The model name, IF-con version and Syscon version are displayed at the bottom of the on-screen display. 892498299 Manual Adjust 1. Track Balance Adjust: 2. Track Gain Adjust: 3. Focus Balance Adjust: 4. Focus Gain Adjust: 5. Eq boost Adjust: 6. Iop: 7. TRV. Level: 8. S curve(FE) Level: 9. RFL(PI) Level: 0. MIRR Time: V v Change Value [RETURN]Return to previous menu 3. Select "6. Iop:" by pressing [6] button on the remote commander. 4. Wait until a hexadecimal number appear in the on-screen display as below. Remocon Diagnosis Menu 0. External Chip Check 1. Servo Parameter Check 2. Drive Manual Operation 3. Emergency History 4. Version Information Model Name :DH_xx TEL 13942296513 IF-con:Ver.xx.xx(xxxx) Syscon:Ver.x.xxx QQ 5. To execute each function, press its number by using numeric button on the remote commander. 6. To release from this mode, press the I/1 button to turn off the system. 3. EXECUTING IOP MEASUREMENT In order to execute IOP measurement, the following standard procedures must be followed. Procedure: 1. From the top menu of Remocon Diagnosis Menu, select "2 Drive Manual Operation" by pressing the [2] button on the remote commander. The following screen appears on the onscreen display Drive Manual Operation 1. Servo Control 2. Track/Layer Jump 3. Manual Adjustment 4. Tray Aging Mode 5. MIRR time Adjust 0. Return to Top Menu Manual Adjust 1. Track Balance Adjust: 2. Track Gain Adjust: 3. Focus Balance Adjust: 4. Focus Gain Adjust: 5. Eq boost Adjust: 6. Iop: 57 7. TRV. Level: 8. S curve(FE) Level: 9. RFL(PI) Level: 0. MIRR Time: 376315150 892498299 V v Change Value [RETURN]Return to previous menu 5. Convert data from hexadecimal to decimal by using conversion table. 6. If the value is smaller than 93 (decimal), then it is OK. However if the value is higher than 93, then BU (base unit) is defective and need to be change. 7. Press the O RETURN button on the remote commander to return to previous menu. 8. Press the [0] button on the remote commander to return to the top menu of Remocon Diagnosis Menu. 9. Press the I/1 button to turn off the system. 4. CHECKING EMERGENCY HISTORY To check the emergency history, please follow the following procedure. Procedure: 1. From the top menu of Remocon Diagnosis Menu, select "3. Emergency History" by pressing the [3] button on the remote commander. The following screen appears on the on-screen display. Emg. History Check Laser Hours CD 999h 59min DVD 999h 59min 01. 01 05 04 04 00 92 46 00 00 00 00 00 00 00 23 45 www . xiaoy u163. com 2. Select "3. Manual Adjustment" by pressing the [3] button on the remote commander. The following screen appears on the on-screen display. 02. 02 02 01 01 00 00 00 00 00 A9 4B 00 00 00 23 45 [Next]Next page [Prev]Prev page [0]Return to Top Menu 19 http://www.xiaoyu163.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

19
HCD-DH3/DH5BT/DH7BT
DVD
SECTION
1. DVD
SERVICE
MODE
GENERAL
DESCRIPTION
This mode let you make diagnosis and adjustment easily by using
the remote commander and the TV screen. The instructions,
diagnostic results, etc. are given on the on-screen display.
2. ENTERING
DVD
SERVICE
MODE
Procedure:
1.
Press the
I
/
1
button to turn on the system.
2.
Press the
DVD
N
button to select the “DVD”.
3.
Press three buttons of
x
,
[VOLUME°+]
and
[PROGRESSIVE]
simultaneously.
4.
The message “SERVICE IN” appears on the fluorescent
indicator tube and top menu of the Remocon Diagnosis Menu
appears on the on-screen display on the TV screen as follows.
The model name, IF-con version and Syscon version are
displayed at the bottom of the on-screen display.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name :DH_xx
IF-con:Ver.xx.xx(xxxx)
Syscon:Ver.x.xxx
5.
To execute each function, press its number by using numeric
button on the remote commander.
6.
To release from this mode, press the
I
/
1
button to turn off the
system.
3. EXECUTING
IOP
MEASUREMENT
In order to execute IOP measurement, the following standard
procedures must be followed.
Procedure:
1.
From the top menu of Remocon Diagnosis Menu, select “2
Drive Manual Operation” by pressing the
[2]
button on the
remote commander. The following screen appears on the on-
screen display
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
2.
Select “3. Manual Adjustment” by pressing the
[3]
button on
the remote commander. The following screen appears on the
on-screen display.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
V
v
Change Value
[RETURN]Return to previous menu
3.
Select “6. Iop:” by pressing
[6]
button on the remote
commander.
4.
Wait until a hexadecimal number appear in the on-screen
display as below.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq boost Adjust:
6. Iop: 57
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
V
v
Change Value
[RETURN]Return to previous menu
5.
Convert data from hexadecimal to decimal by using conversion
table.
6.
If the value is smaller than 93 (decimal), then it is OK. However
if the value is higher than 93, then BU (base unit) is defective
and need to be change.
7.
Press the
O
RETURN
button on the remote commander to
return to previous menu.
8.
Press the
[0]
button on the remote commander to return to the
top menu of Remocon Diagnosis Menu.
9.
Press the
I
/
1
button to turn off the system.
4. CHECKING
EMERGENCY
HISTORY
To check the emergency history, please follow the following
procedure.
Procedure:
1.
From the top menu of Remocon Diagnosis Menu, select “3.
Emergency History” by pressing the
[3]
button on the remote
commander. The following screen appears on the on-screen
display.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
01. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
02. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next]Next page [Prev]Prev page
[0]Return to Top Menu