Sony PZW-4000 Operating Instructions - Page 18

Synchronization Reference Signals

Page 18 highlights

01080 3. Preparation Synchronization Reference Signals The sync reference signal generator of the unit synchronizes to a reference signal input on the REF. VIDEO INPUT connector or to an input video signal. External sync depends on the setting of OUT REF on the HOME page of the function menu and on the selected input signal. The output video signals are always synchronized to the internal sync reference signal. Input to SDI INPUT connector a) Yes Yes No No Input to REF. VIDEO INPUT connector Yes No Yes No Setting of OUT REF on the HOME page INPUT REF Synchronize to the input signal on the SDI INPUT connector Synchronize to the input signal on the REF. VIDEO INPUT connector Synchronize to the input signal on the SDI INPUT connector No external sync No external sync Synchronize to the input signal on the REF. VIDEO INPUT connector No external sync No external sync a) Same as when INT SG on the P1 INPUT page of the function menu is set to "ON". Setting setup menu item 105 REFERENCE ALARM to "ON" causes the STOP button to flash when the clip is not synchronized to the reference signal. [Note] While the internal SG signal is being recorded, if the REF. VIDEO INPUT signal is disconnected and reconnected with OUT REF set to REF, or the SDI INPUT signal is disconnected and reconnected with OUT REF set to INPUT, the recording may be disrupted.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87

000
3. Preparation
18
The sync reference signal generator of the unit
synchronizes to a reference signal input on the
REF. VIDEO INPUT connector or to an input video
signal. External sync depends on the setting of
OUT REF on the HOME page of the function menu
and on the selected input signal. The output video
signals are always synchronized to the internal
sync reference signal.
Input to SDI INPUT
connector
a)
Input to REF. VIDEO
INPUT connector
Setting of OUT REF on the HOME page
INPUT
REF
Yes
Yes
Synchronize to the input
signal on the SDI INPUT
connector
Synchronize to the input
signal on the REF. VIDEO
INPUT connector
Yes
No
Synchronize to the input
signal on the SDI INPUT
connector
No external sync
No
Yes
No external sync
Synchronize to the input
signal on the REF. VIDEO
INPUT connector
No
No
No external sync
No external sync
a) Same as when INT SG on the P1 INPUT page of the
function menu is set to “ON”.
Setting setup menu item 105 REFERENCE ALARM
to “ON” causes the STOP button to flash when the
clip is not synchronized to the reference signal.
[Note]
While the internal SG signal is being recorded, if the REF.
VIDEO INPUT signal is disconnected and reconnected with
OUT REF set to REF, or the SDI INPUT signal is disconnected
and reconnected with OUT REF set to INPUT, the recording
may be disrupted.
Synchronization Reference Signals