Sony STR-DH540 Operating Instructions - Page 55
Easy Setup, Speaker Settings menu, Auto Calibration, To check the Auto Calibration, results - codes
View all Sony STR-DH540 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Easy Setup Re-runs the Easy Setup to make the basic settings. Follow the on-screen instructions (page 28). Speaker Settings menu You can adjust each speaker manually. You can also adjust the speaker levels after the Auto Calibration is completed. Note The speaker settings are only for the current seating position. x Auto Calibration Lets you perform Auto Calibration from your seating position. 1 Follow the instructions on the TV screen, then press . The measurement starts in five seconds. The measurement process will take approximately 30 seconds with a test tone. When the measurement ends, a beep sounds and the screen switches. Note If an error code appears on the screen, see "Message list after Auto Calibration measurement" (page 56). 2 Select the item you want, then press . • Retry: Performs the Auto Calibration again. • Save&Exit: Save the measurement results and exits the setting process. • WRN Check: Displays warning related to the measurement results. See "Message list after Auto Calibration measurement" (page 56). • Exit: Exits the setting process without saving the measurement results. 3 Save the measurement result. Select "Save&Exit" in step 2. Note If you reposition your speaker, we recommend that you perform Auto Calibration again to enjoy the surround sound. Tips • You can change the unit of distance in "Distance Unit" in the Speaker Settings menu (page 58). • The size of a speaker ("Large"/"Small") is determined by the low frequency characteristics. The measurement results may vary, depending on the position of the optimizer microphone and speakers, and the shape of the room. It is recommended that you apply the measurement results. However, you can change those settings in the Speaker Settings menu. Save the measurement results first, then try to change the settings. To check the Auto Calibration results To check error code or warning message obtained in "Auto Calibration" (page 55), proceed with the following steps. Select "WRN Check" in step 2 in "Auto Calibration" (page 55) then press . If a warning message appears, check the message and use the receiver without change. Or if necessary, perform Auto Calibration again. When "Error Code" appears Check the error and perform Auto Calibration again. 1 Press . "Retry?" appears on the TV screen. 2 Select "Yes", then press . 3 Repeat steps 1 to 3 in "Auto Calibration" (page 55). Adjusting Settings 55GB