Sony VPL-FHZ65 Operating Instructions - Page 47

Port No., Timeout, Host Address, Start PJ Link Service, Requires Authentication, Password

Page 47 highlights

be changed from the factory setting to avoid unnecessary access to the projector from other computers. -Port No.: Input the server port of PJ Talk. The factory default setting is "53484." -Timeout: Input the time (seconds) until PJ Talk communication is terminated in the case that it is disconnected. The factory default setting is "30." -Host Address: Input the IP address that the PJ Talk server is allowed to receive. If no IP address is input, receiving commands will be allowed from any IP address. From the moment the IP address is input, access will be allowed only from that input IP address. For security reasons, it is recommended to input an IP address to restrict access. (d) Set PJ Link. PJ Link Service setting area (e) Set the system service. System service setting area Service button Start DDDP Service: Set DDDP to enabled or disabled. For details, refer to the DDDP specifications in the reference from AMX Corporation. The function is disabled at the factory default. Crestron Control: For details, refer to the specifications in product catalogues, etc., from Crestron Corporation. -IP Address: Input the Crestron system server. -IP ID: Input the IP ID for the CIP protocol. -Port No.: Input the port number for the CIP protocol server. PJ Link button Start PJ Link Service: Set PJ Link to enabled or disabled. Items for PJ Link are enabled only when this function is enabled. This function is enabled at the factory setting. -Requires Authentication: Set the authentication for PJ Link to enabled or disabled. -Password: Input the authentication password for PJ Link. For the factory default password, refer to the PJ Link specifications. 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

47
be changed from the factory setting to
avoid unnecessary access to the
projector from other computers.
-Port No.:
Input the server port of PJ Talk. The
factory default setting is “53484.”
-Timeout:
Input the time (seconds) until PJ Talk
communication is terminated in the case
that it is disconnected. The factory
default setting is “30.”
-Host Address:
Input the IP address that the PJ Talk
server is allowed to receive. If no IP
address is input, receiving commands
will be allowed from any IP address.
From the moment the IP address is input,
access will be allowed only from that
input IP address. For security reasons, it
is recommended to input an IP address
to restrict access.
(d) Set PJ Link.
Start PJ Link Service:
Set PJ Link to enabled or disabled. Items
for PJ Link are enabled only when this
function is enabled. This function is
enabled at the factory setting.
-Requires Authentication:
Set the authentication for PJ Link to
enabled or disabled.
-Password:
Input the authentication password for PJ
Link. For the factory default password,
refer to the PJ Link specifications.
(e) Set the system service.
Start DDDP Service:
Set DDDP to enabled or disabled. For
details, refer to the DDDP specifications
in the reference from AMX Corporation.
The function is disabled at the factory
default.
Crestron Control:
For details, refer to the specifications in
product catalogues, etc., from Crestron
Corporation.
-IP Address:
Input the Crestron system server.
-IP ID:
Input the IP ID for the CIP protocol.
-Port No.:
Input the port number for the CIP
protocol server.
PJ Link button
PJ Link Service setting area
Service button
System service setting area