Stihl RMA 370 Product Instruction Manual - Page 31
Troubleshooting
View all Stihl RMA 370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Troubleshooting English Always remove the battery before carrying out any work on the power tool. Condition Cause Remedy No electrical contact between power tool Remove battery, check contacts and refit and battery battery Battery discharged Charge the battery Machine does not run when switched on (1 light emitting diode on battery flashes green) Battery too hot / too cold Allow battery to cool down / at tempera- (1 light emitting diode on battery glows red) tures of about 59°F - 68°F (15°C - 20°C), allow battery to warm up slowly Fault in battery (4 light emitting diodes on battery flash red) Take the battery out of the power tool and refit it. Switch on the power tool - if the light emitting diodes still flash, the battery is faulty and must be replaced. Fuse key not fitted Fit the fuse key Fault in fuse key Replace fuse key Power tool too hot Allow power tool to cool down (3 light emitting diodes on battery glow red) Electromagnetic interference or fault in power tool (3 light emitting diodes on battery flash red) Take the battery out of the power tool and refit it. Switch on the power tool - if the light emitting diodes still flash, the power tool is faulty and must be checked by a servicing dealer 1). Motor overloaded by high or damp grass Do not start motor in high grass, adjust cutting height to suit conditions Mower housing blocked Clean mower housing Moisture in power tool and/or battery Allow power tool/battery to dry RMA 370 29