TASCAM DM-24 Installation and Use Owners Manual - Page 34

Parts of the DM-24-Rear panel

Page 34 highlights

4 - Parts of the DM-24-Rear panel S Automation control keys and indicators These keys (REHEARSE, WRITE, TRIM and REVERT) are used to control the automa- tion functions. These keys have other functions, as selected by the 2ND F key (F). NOTE Although some of these keys have similar names to other keys on the DM-24, note that their functions are restricted to automation operations. Rear panel The rear panel of the DM-24 houses the digital audio and control connections. 1 23 4 56 7 8 9 A B C NOTE Only use TASCAM-supplied and TASCAM-approved cables when making digital audio and control connections to the DM-24. Though the cables and connectors may resemble computer cables, they serve different purposes, and meet a different set of specifications. The use of cables other than TASCAM cables will at best cause the equipment to work erratically, and at worst cause damage to the equipment. If the use of cables other than TASCAM cables causes or results in damage, the warranty is voided. 1 TO METER This 25-pin 'D'-sub connector is used to connect the DM-24 and the optional MU-24/ DM meter unit. 2 ADAT [IN, OUT] Use these "lightpipe" con- nectors to connect ADAT-compatible units to the DM-24 with a Toslink-type optical cable. Each of these connectors carries eight digital audio input or outputs channels. DE The input may be used as a clock source, and routed to any of the three groups of eight input channels (1 through 8, 9 through 16, 17 through 24). 3 WORD SYNC [OUT/THRU, IN] and switch These BNC connectors are used for word sync. The switch controls the behavior of the connectors (75Ω input impedance and switching between OUT and THRU functions) as described here: Position Left Center Right 75Ω IN termination? No No Yes OUT/THRU Thru Out Out A THRU setting means that the connector echoes the word sync signal received at the IN. An OUT setting means that the DM-24 originates a word sync signal (and is therefore to be the word sync master for the system). 34 TASCAM DM-24 Reference Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

4 – Parts of the DM-24—Rear panel
34
TASCAM DM-24 Reference Manual
S
Automation control keys and
indicators
These keys (
REHEARSE
,
WRITE
,
TRIM
and
REVERT
) are used to control the automa-
tion functions. These keys have other functions, as
selected by the
2ND F
key (
F
).
NOTE
Although some of these keys have similar names to
other keys on the DM-24, note that their functions are
restricted to automation operations.
Rear panel
The rear panel of the DM-24 houses the digital audio
and control connections.
NOTE
Only use TASCAM-supplied and TASCAM-approved
cables when making digital audio and control connec-
tions to the DM-24. Though the cables and connectors
may resemble computer cables, they serve different
purposes, and meet a different set of specifications. The
use of cables other than TASCAM cables will at best
cause the equipment to work erratically, and at worst
cause damage to the equipment.
If the use of cables other than TASCAM cables causes or
results in damage, the warranty is voided.
1
TO METER
This 25-pin ‘D’-sub connector is
used to connect the DM-24 and the optional MU-24/
DM meter unit.
2
ADAT [IN, OUT]
Use these “lightpipe” con-
nectors to connect ADAT-compatible units to the
DM-24 with a Toslink-type optical cable. Each of
these connectors carries eight digital audio input or
outputs channels.
The input may be used as a clock source, and routed
to any of the three groups of eight input channels (1
through 8, 9 through 16, 17 through 24).
3
WORD SYNC [OUT/THRU, IN] and
switch
These BNC connectors are used for word
sync. The switch controls the behavior of the connec-
tors (75
input impedance and switching between
OUT and THRU functions) as described here:
A
THRU
setting means that the connector echoes the
word sync signal received at the
IN
. An
OUT
setting
means that the DM-24 originates a word sync signal
(and is therefore to be the word sync master for the
system).
1
23
4
56 7
8
9
A
B
C
DE
Position
75
IN
termination?
OUT/THRU
Left
No
Thru
Center
No
Out
Right
Yes
Out