11 - Machine Control/Location-DTRS devices DA-38 The DA-38 does not include quite so many options as the DA-98. Input monitoring is not possible, but track copying is available in the same way as for the DA-98. Since the DA-38 does not include a timecode generator, the range of options available in the TC/SYNC section is more limited, being restricted only to setting the machine offset value. The clock sources are restricted to internal and word. DA-88 This provides the following facilities as shown on the screen here: Similar to the DA-38, digital input can be switched on and off (that is, between analog and digital inputs). The track delay time can be set individually, as well as a global setting. Use the PODs here to make the adjustment. If an SY-88 card is fitted in the DA-88, the timecode settings can be made in the same way as for the DA98 timecode. Punch preroll time only can be set (postroll cannot be set). Clock source options are restricted to internal, video and word. 92 TASCAM DM-24 Reference Manual