436 Appendix A: System Routines - Display display_statements Declaration: Category(ies): Description: HANDLE display_statements (EStackIndex i, Boolean replace_newlines, Boolean full_precision) Display Converts the external-tokenized form of an expression, statement, or group of statements to linear ASCII text form. Inputs: i - EStackIndex of external-tokenized expression, statement, or group of statements. replace_newlines - TRUE to replace '\r' characters with ':'; FALSE to leave '\r' characters as-is. full_precision - TRUE to display floating-point numbers with full available precision. FALSE to display floating-point numbers with precision determined by MODE screen settings. Outputs: Returns the HANDLE to a heap packet which contains the ASCII text result; returns H_NULL if memory full. Assumptions: None Side Effects: May cause heap compression. Availability: All versions of the TI-89 / TI-92 Plus. TI-89 / TI-92 Plus Differences: None See Also: Parse1DExpr Example: /* Assume i is the EStackIndex of the tagged floating-point number 3.1415926535898 and that the current MODE setting for Display Digits is FLOAT 6, then */ HANDLE h; h = display_statements (i, TRUE, TRUE); /* returns a HANDLE to a memory block containing the full precision ASCII text 3.1415926535898. However, */ h = display_statements (i, TRUE, FALSE); /* returns a HANDLE to a memory block containing the FLOAT 6 precision ASCII text 3.14159. */ TI-89 / TI-92 Plus Developer Guide Not for Distribution Beta Version January 26, 2001