Thermador T36FT820NS Instructions for Use - Page 28
Customer service,
View all Thermador T36FT820NS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
en-us Eliminating faults Fault Cause and troubleshooting Water is dripping from the water dispenser. Air is in the water system. ▶ Keep dispensing water until it contains no more air. The water dispenser is not functioning. There is no water supply. ▶ Ensure that there is a water supply and that the shut-off valve on the water con- nection is open. Contact an installer if necessary. Kink in the water hose. ▶ Turn off the water supply and straighten the kink in water hose. If necessary, replace the water hose. Ice cube production is low. The appliance has only recently been connected. ▶ Wait approximately 4 hours until the first batch of ice cubes is ready. The freezer compartment has been opened frequently or for an extended period of time. ▶ Check ice cube production after a few hours. Low water pressure. ▶ Check the water pressure of the water supply system or the external water filter system. Connect the appliance only to a water connection with sufficient water pressure. The water filter is blocked. ▶ Change the water filter. → Page 20 Food or objects are blocking the fill level sensor for the ice cube maker. ▶ Remove all food or objects from the ice storage container. The ice cube maker is not function- Ice cube production is switched off. ing. ▶ Switch on ice cube production. → Page 21 There is no water supply. ▶ Ensure that there is a water supply and that the shut-off valve on the water con- nection is open. Contact an installer if necessary. Kink in the water hose. ▶ Turn off the water supply and straighten the kink in water hose. If necessary, replace the water hose. The ice cube maker has no current. ▶ Call customer service. → "Customer service", Page 29 The appliance hums, bubbles, Not an issue. A motor is running, e.g. refrigerating unit, fan. Refrigerant is flowing buzzes, gargles, clicks, crackles or through the pipes. The motor, switches, solenoid valves or water valves are switch- rumbles. ing on or off. Automatic defrosting is running. No action required. The appliance makes noises. The appliance is not level. ▶ Align the appliance using a bubble level and the screw feet. The appliance is not free-standing. ▶ Observe the minimum clearances for the appliance. Fittings wobble or stick. ▶ Check the removable fittings and, if required, replace these. Bottles or containers are touching. ▶ Move the bottles or containers away from each other. Super freezing is switched on. No action required. 28