Thermador VCIN54GWS Installation Instructions - Page 16

Blower motor installation

Page 16 highlights

Blower motor installation Blower and Circuit Breaker Ratings Blower SKU Remote Remote Remote In-line In-line Integral Integral VTR630 VTR1030 VTR1330 VTI610 VTI1010 VTN630 VTN1090 Voltage Current Breaker Amp 120 4.2 15 120 5.7 15 120 8.5 15 / 20 120 4.2 15 120 5.7 15 120 4.2 15 120 5.4 15 Integral blower installation Integral blower models are integrated into the hood at the time of installation. Integral blowers should be installed after the hood is mounted to the wall. For complete installation instructions see the instructions supplied with the blower unit. inches (mm) 18⅞" (473) 10⅞" (275) 9 CAUTION To reduce the risk of fire and electric shock, install this range hood only with the blowers listed in the 8¼" Ventilation Planning Guide. (208) 13⅛" (335) NOTE: Cutting the plug of the blower will void the warranty or eligibility for return or exchange. All blower models are sold separately. Use only Thermador blowers with these ventilation hoods. See the Ventilation Planning Guide for recommended blowers. Contact Customer Service for additional options. All hood models are rated for 120V AC installed with a blower listed in the table above, using a 15 amp dedicated circuit breaker. The VTR1330 blower in conjunction with a PHxxGWS requires a 20 amp circuit breaker. Blower selection will vary based on the volume of air that needs moved and the length and location of the duct run. For long duct runs with multiple turns and bends, consider using a more powerful blower. For the most efficient air flow exhaust, use a straight run or as few elbows as possible (refer to "Ductwork Preparation"). 1. The blower is attached to the hood using weld studs on the mounting plate. Guide the motor mounting plate over the studs. 2. Attach four (4) nuts (included with hood) to the weld studs. Tighten nuts with a 11/32'' nut driver to secure the blower to the hood. Page. 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Page. 16
Blower motor installation
Blower and Circuit Breaker Ratings
9
CAUTION
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in the
Ventilation Planning Guide
.
NOTE:
Cutting the plug of the blower will void the
warranty or eligibility for return or exchange.
All blower models are sold separately. Use only
Thermador blowers with these ventilation hoods. See the
Ventilation Planning Guide
for recommended blowers.
Contact Customer Service for additional options.
All hood models are rated for 120V AC installed with a
blower listed in the table above, using a 15 amp
dedicated circuit breaker. The VTR1330 blower in
conjunction with a PHxxGWS requires a 20 amp circuit
breaker.
Blower selection will vary based on the volume of air that
needs moved and the length and location of the duct run.
For long duct runs with multiple turns and bends, consider
using a more powerful blower. For the most efficient air
flow exhaust, use a straight run or as few elbows as
possible (refer to “Ductwork Preparation”).
Integral blower installation
Integral blower models are integrated into the hood at the
time of installation. Integral blowers should be installed
after the hood is mounted to the wall.
For complete installation instructions see the instructions
supplied with the blower unit.
1.
The blower is attached to the hood using weld studs
on the mounting plate. Guide the motor mounting
plate over the studs.
2.
Attach four (4) nuts (included with hood) to the weld
studs. Tighten nuts with a 11/32'' nut driver to secure
the blower to the hood.
Blower
SKU
Voltage
Current
Breaker
Amp
Remote
VTR630
120
4.2
15
Remote
VTR1030
120
5.7
15
Remote
VTR1330
120
8.5
15 / 20
In-line
VTI610
120
4.2
15
In-line
VTI1010
120
5.7
15
Integral
VTN630
120
4.2
15
Integral
VTN1090
120
5.4
15
10
"
10
"
10
"
(275)
(275)
(275)
13
"
13
"
13
"
(335)
(335)
(335)
8
¼
"
(20
8
)
8
¼
"
(20
8
)
8
¼
"
(20
8
)
1
8
"
1
8
"
1
8
"
(473)
(473)
(473)
inches (mm)