Toshiba TLP-X2000 User Manual - Page 26

Lamp replacement - service manual

Page 26 highlights

Lamp replacement A lamp is consumable supplies. If used for extended periods, images will appear dark, and the lamp could burn out. This is characteristic of a lamp, and is not malfunction. (The lifetime of the lamp depends on condition of use.) If this happens, replace it with a new one. WARNING • If the projector is mounted on the ceiling, it is recommended to use your Toshiba dealership when the lamp has to be exchanged. Uncovering the lamp while the projector is mounted on a ceiling may lead to a danger of damage from falling pieces of glass if the lamp is broken. Besides, working at high elevations can also be hazardous. Do not attempt to replace the lamp by yourself. • When replacement is required, be sure to use TLPLW11 (sold separately). CAUTION • If you have been using the projector, the lamp will be very hot, and may cause burn injuries. Wait for the lamp to cool (for longer than 1 hour) before replacing it. • If the lamp should break, please handle with care to avoid injury due to broken pieces ( p.49 ) and contact your dealer for repair service. 1 Unplug power cord. 2 Wait until lamp is sufficiently cooled. Wait for at least 1 hour. 3 Remove the lamp cover. 3 Loosen the two screws, raise the lamp cover Lamp cover with your fingers as shown to remove the lamp cover. Use care to avoid any damage to nails and/or tip of your finger(s). If you have any 1 2 difficulty in removal, you can use a screwdriver or any other smaller tool for your convenience. 4 Pull out the lamp. 4 Loosen the three lamp locking screws, pull up the 1 handle, and remove the lamp. 2 50 5 Mount the new lamp. 5 2 Align the orientation, press down the new lamp until the bottom is reached, and lock in place using 1 the three lamp locking screws. 6 Replace the lamp cover. Align the cover, and press it in, then tighten the screws loosened in step 3 until the lamp cover is no longer loose. 7 Reset the lamp time. See the lamp's manual for instructions on resetting the lamp time. Notes and Precautions • The [Lamp time] item in the Status display menu indicates the time of lamp use (as a rough guide) p.44 • Please replace the lamp after 2000 hours of use with [Lamp power] in the Default setting 1 menu set to [Standard], and 3000 hours of use with [Lamp power] in the Default setting 1 menu set to [Low]. p.42 • There are cases that the lamp can not work before the above mentioned period expires or before the replacement message is displayed. • Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the projector may fail to be powered on or the lamp may fail to come on. • Always replace the lamp with a new one. • The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.) About lamp replacement messages • The lamp replacement message of this projector displays an appropriate period according to the use period for [Standard] / [Low] of the [Lamp power] respectively. • When the replacement time approaches, the message of "The lamp life is ending. Please change the lamp." and the icon are displayed every time the power is turned on. This display disappears when you press the button. Used Lamps This projector's lamps contain trace amounts of environmentally harmful inorganic mercury. Be careful not to break used lamps, and dispose of them in accordance with local regulations. 51 Maintenance

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

51
Maintenance
50
5
Mount the new lamp.
Align the orientation, press down the new lamp
until the bottom is reached, and lock in place using
the three lamp locking screws.
6
Replace the lamp cover.
Align the cover, and press it in, then tighten the
screws loosened in step
3
until the lamp cover is
no longer loose.
7
Reset the lamp time.
See the lamp’s manual for instructions on resetting
the lamp time.
Notes and Precautions
The [
Lamp time
] item in the
Status display
menu indicates the time of lamp use (as a
rough guide)
p.44
Please replace the lamp after 2000 hours of use with [
Lamp power
] in the
Default
setting 1
menu set to [
Standard
], and 3000 hours of use with [
Lamp power
] in the
Default setting 1
menu set to [
Low
].
p.42
There are cases that the lamp can not work before the above mentioned period expires
or before the replacement message is displayed.
Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the
projector may fail to be powered on or the lamp may fail to come on.
Always replace the lamp with a new one.
The lamp is made out of glass. Do not touch the glass surface with your bare hands,
bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.)
Used Lamps
This projector’s lamps contain trace amounts of environmentally harmful inorganic
mercury. Be careful not to break used lamps, and dispose of them in accordance with
local regulations.
1
Unplug power cord.
2
Wait until lamp is sufficiently cooled.
Wait for at least 1 hour.
3
Remove the lamp cover.
Loosen the two screws, raise the lamp cover
with your fingers as shown to remove the lamp
cover. Use care to avoid any damage to nails
and/or tip of your finger(s). If you have any
difficulty in removal, you can use a screwdriver
or any other smaller tool for your convenience.
4
Pull out the lamp.
Loosen the three lamp locking screws, pull up the
handle, and remove the lamp.
Lamp cover
2
1
1
2
3
4
A lamp is consumable supplies. If used for extended periods, images will appear dark, and
the lamp could burn out. This is characteristic of a lamp, and is not malfunction. (The lifetime
of the lamp depends on condition of use.) If this happens, replace it with a new one
.
WARNING
If the projector is mounted on the ceiling, it is recommended to use your Toshiba dealer-
ship when the lamp has to be exchanged.
Uncovering the lamp while the projector is mounted on a ceiling may lead to a danger
of damage from falling pieces of glass if the lamp is broken. Besides, working at high
elevations can also be hazardous. Do not attempt to replace the lamp by yourself.
When replacement is required, be sure to use TLPLW11 (sold separately).
CAUTION
If you have been using the projector, the lamp will be very hot, and may cause burn
injuries. Wait for the lamp to cool (for longer than 1 hour) before replacing it.
If the lamp should break, please handle with care to avoid injury due to broken pieces
(
p.49
) and contact your dealer for repair service.
5
1
2
Lamp replacement
The lamp replacement message of this projector displays an appropriate period
according to the use period for [
Standard
] / [
Low
] of the [
Lamp power
] respectively.
When the replacement time approaches, the message of “The lamp life is ending.
Please change the lamp.” and the icon
are displayed every time the power is
turned on. This display disappears when you press the
button.
About lamp replacement messages