Tripp Lite PDU3VSR3G60 Owner's Manual for High Voltage 3-Phase PDU 932906 - Page 3

Installation

Page 3 highlights

Installation Connecting the PDU 2-1 Each model is equipped with 1 of 8 different input plugs. 16A Red IEC 30A Blue IEC 60A Blue IEC Hubbell 309 3P+N+E 309 3P+E 309 3P+E CS8365C L15-30P L21-30P L21-20P L15-20P PDU3VSR-Switched, Metered and Networked-0U, Vertical Strip Cabinet Style Model # PDU3VSR3G30 PDU3VSR10G30 PDU3VSR3G60 PDU3VSR10G60 PDU3VSR3H50 PDU3VSR10H50 PDU3VSR3L1530 PDU3VSR10L1530 PDU3VSR3L2130 PDU3VSR10L2130 PDU3VSR3L2120 PDU3VSR10L2120 PDU3VSR3L1520 PDU3VSR10L1520 PDU3XVSR3G16 PDU3XVSR10G16 Input Plug Balanced Max Amps Output (Limited by Input Output Current Cord input plug) Voltage Voltage per Phase Length Outlets Outlet Control 30A Blue IEC 309 3P+E 24 208 208 13.9 A 60A Blue IEC 309 3P+E 35 208 208 20.0 A Hubbell CS8365C 35 208 208 20.0 A L15-30P L21-30P 24 24 208 208 13.9 A 10 ft. or 3 ft. 3 Banks of (7) C13s and (1) C19 Yes L21-20P 16 L15-20P 16 16A Red IEC 309 3P+N+E 16 208 208 9.2 A 230/ 400 230 16.0 A PDU3VN-Metered and Networked-0U, Vertical Strip Cabinet Style Model # PDU3VN3G30 PDU3VN10G30 PDU3VN3G60 PDU3VN10G60 PDU3VN3H50 PDU3VN10H50 PDU3VN3L1530 PDU3VN10L1530 PDU3VN3L2130 PDU3VN10L2130 PDU3VN3L2120 PDU3VN10L2120 PDU3VN3L1520 PDU3VN10L1520 PDU3XVN3G16 PDU3XVN10G16 Input Plug Balanced Max Amps Output (Limited by Input Output Current Cord input plug) Voltage Voltage per Phase Length Outlets Outlet Control 30A Blue IEC 309 3P+E 24 208 208 13.9 A 60A Blue IEC 309 3P+E 35 208 208 20.0 A Hubbell CS8365C 35 208 208 20.0 A L15-30P L21-30P 24 24 208 208 13.9 A 10 ft. or 3 ft. 3 Banks of (10) C13s and (2) C19 No L21-20P 16 L15-20P 16 16A Red IEC 309 3P+N+E 16 208 208 9.2 A 230/ 400 230 16.0 A 3 201104185 93-2906.indb 3 5/18/2011 1:36:00 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

3
Installation
Connecting the PDU
2-1
Each model is equipped with 1 of 8 different input plugs.
16A Red IEC
309 3P+N+E
30A Blue IEC
309 3P+E
60A Blue IEC
309 3P+E
Hubbell
CS8365C
L15-30P
L21-30P
L21-20P
L15-20P
PDU3VSR-Switched, Metered and Networked—0U, Vertical Strip Cabinet Style
Model #
Input Plug
Max Amps
(Limited by
input plug)
Input
Voltage
Output
Voltage
Balanced
Output
Current
per Phase
Cord
Length
Outlets
Outlet
Control
PDU3VSR3G30
PDU3VSR10G30
30A Blue IEC 309 3P+E
24
208
208
13.9 A
10 ft.
or 3 ft.
3 Banks of
(7) C13s and
(1) C19
Yes
PDU3VSR3G60
PDU3VSR10G60
60A Blue IEC 309 3P+E
35
208
208
20.0 A
PDU3VSR3H50
PDU3VSR10H50
Hubbell CS8365C
35
208
208
20.0 A
PDU3VSR3L1530
PDU3VSR10L1530
L15-30P
24
208
208
13.9 A
PDU3VSR3L2130
PDU3VSR10L2130
L21-30P
24
PDU3VSR3L2120
PDU3VSR10L2120
L21-20P
16
208
208
9.2 A
PDU3VSR3L1520
PDU3VSR10L1520
L15-20P
16
PDU3XVSR3G16
PDU3XVSR10G16
16A Red IEC 309 3P+N+E
16
230/
400
230
16.0 A
PDU3VN-Metered and Networked—0U, Vertical Strip Cabinet Style
Model #
Input Plug
Max Amps
(Limited by
input plug)
Input
Voltage
Output
Voltage
Balanced
Output
Current
per Phase
Cord
Length
Outlets
Outlet
Control
PDU3VN3G30
PDU3VN10G30
30A Blue IEC 309 3P+E
24
208
208
13.9 A
10 ft.
or 3 ft.
3 Banks of
(10) C13s
and (2) C19
No
PDU3VN3G60
PDU3VN10G60
60A Blue IEC 309 3P+E
35
208
208
20.0 A
PDU3VN3H50
PDU3VN10H50
Hubbell CS8365C
35
208
208
20.0 A
PDU3VN3L1530
PDU3VN10L1530
L15-30P
24
208
208
13.9 A
PDU3VN3L2130
PDU3VN10L2130
L21-30P
24
PDU3VN3L2120
PDU3VN10L2120
L21-20P
16
208
208
9.2 A
PDU3VN3L1520
PDU3VN10L1520
L15-20P
16
PDU3XVN3G16
PDU3XVN10G16
16A Red IEC 309 3P+N+E
16
230/
400
230
16.0 A
201104185 93-2906.indb
3
5/18/2011
1:36:00 PM