Uniden BCD396T English Owners Manual - Page 57
Using the Cloning Options, Wired Cloning - programming cable
View all Uniden BCD396T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Use the included connection cable to connect your scanner to another BCD396T scanner or your personal computer. Menu Settings PC Control PC Control Lets you set the baud rate your scanner uses to communicate with a personal computer. • Off The baud rate is not set. • 9600 bps The baud rate is set to 9600 bps. • 19200 bps The baud rate is set to 19,200 bps. • 38400 bps The baud rate is set to 38,400 bps. • 57600 bps The baud rate is set to 57,600 bps. • 115200 bps The baud rate is set to 115,200 bps. Using the Cloning Options Lets you set your scanner as a master (source) or slave (recipient), letting you transfer programming to or from another BCD396T scanner. See "Wired Cloning" on Page 57 and "On-Air Cloning" on Page 58. Wired Cloning Menu Xfer Information Wired Clone • Master Sets the scanner to be the source scanner. • Slave Sets the scanner to be the recipient scanner. To clone (copy) data directly from one BCD396T scanner to another BCD396T scanner, you must first connect the scanners to each other using the included connection cables and a DB9 null modem adapter and DB9 gender changer (neither included), available at most computer stores. Then you must set one scanner as the source and the other as the destination. Plug the smaller end of each of the included connection cables into Remote on the right side of each scanner. Then connect the other end of the cables together using the null modem connector and gender changer. Other Settings 57