Whirlpool WED7990FW Installation Guide - Page 12
Wire Direct Wire Connection
![]() |
View all Whirlpool WED7990FW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
2. Attach direct wire cable to strain relief 2. Prepare to connect neutral ground wire and neutral wire E B A Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable. If your wiring looks like this: 4-wire direct connection: Go to "4-Wire Direct Wire Connection." 3-wire direct connection: Go to "3-Wire Direct Wire Connection." 4-Wire Direct Wire Connection IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections. 1. Prepare your 4-wire cable for direct connection 31 (89 ⁄2m" m) (251m" m) Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A). 3. Connect neutral ground wire and neutral wire B E C Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw. (127 5" mm) 4. Connect ground wire Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. A Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 11/2" (38 mm) from remaining 3 wires. Strip insulation back 1" (25 mm). F Shape ends of wires into hooks. Connect ground wire (green or bare) (F) of direct wire cable under green external ground conductor screw (A). Tighten screw. 12
![](/manual_guide/products/whirlpool-wed9290fw-installation-guide-2be0cfe/12.png)