Whirlpool WED7990FW Installation Guide - Page 14

Connect Outlet Hose

Page 14 highlights

2. Connect neutral ground wire and neutral wire B E C Connect Outlet Hose 1. Attach hose Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center, terminal block screw (B). Tighten screw. 3. Connect remaining wires Attach the goose-neck fitting of the provided 6 ft. (1829 mm) drain hose to the drain valve at the bottom of dryer back panel. Screw on coupling by hand until it is seated on valve connector. 2. Tighten coupling Place ends of remaining wires under outer terminal block screws. Tighten screws. 4. Connect external ground wire Using channel locks, tighten the coupling an additional two-thirds turn. NOTE: Do not over tighten. Damage to the coupling can result. 3. Secure drain hose system Laundry Tub Standpipe Wall 4.5" 4.5" 4.5" (114 mm) (114 mm) (114 mm) A G Connect a separate copper ground wire (G) under the green external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Connect Outlet Hose." Secure drain hose to laundry tub leg, drain standpipe, or inlet hoses for wall standpipe with cable tie. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

14
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center,
terminal block screw (B). Tighten screw.
Place ends of remaining wires under outer terminal block
screws. Tighten screws.
2.
Connect neutral ground wire and
neutral wire
C
E
B
3.
Connect remaining wires
Connect a separate copper ground wire (G) under the green
external ground conductor screw (A) to an adequate ground.
Finally, reinsert tab of terminal block cover into slot of dryer
rear panel. Secure cover with hold-down screw. Now, go to
“Connect Outlet Hose.”
4.
Connect external ground wire
G
A
Connect Outlet Hose
1.
Attach hose
Attach the goose-neck fitting of the provided 6 ft. (1829 mm)
drain hose to the drain valve at the bottom of dryer back
panel. Screw on coupling by hand until it is seated on valve
connector.
2.
Tighten coupling
Using channel locks, tighten the coupling an additional
two-thirds turn.
NOTE:
Do not over tighten. Damage to the coupling can
result.
4.5
"
(114 mm)
4.5"
(114 mm)
4.5
"
(114 mm)
4.5"
(114 mm)
4.5
"
(114 mm)
4.5"
(114 mm)
3.
Secure drain hose system
Secure drain hose to laundry tub leg, drain standpipe, or inlet
hoses for wall standpipe with cable tie.
Laundry Tub
Standpipe
Wall