4-11. Adjusting the air pressure [6] 4. INSTALLATION Lift up the handle (2) of the regulator (1) and then turn it to adjust the air pressure to 0.5 MPa. After adjustment is complete, push the handle (2) downward to lock it. 3975M 4-12. Adjusting the speed controller [7] You can adjust the lifting and lowering speeds for the work clamp using the knobs on the valves. • When the upper knob is tightened, the lifting speed becomes slower. When it is loosened, the lifting speed becomes faster. • When the lower knob is tightened, the lowering speed becomes slower. When it is loosened, the lowering speed becomes faster. Upper knob Lower knob Valve 2 Reference adjustments Valve 1 Upper knob Lower knob Valve 2 Upper knob Lower knob Fully tighten Fully tighten and then loosen by 8 turns Fully tighten and then loosen by 5 turns Fully tighten Valve 1 You can operate the work clamp when the power is turned off by pressing the manual buttons (1). 3976M BAS-342G 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

4. INSTALLATION
11
BAS-342G
4-11. Adjusting the air pressure [6]
Lift up the handle (2) of the regulator (1) and then turn it to
adjust the air pressure to 0.5 MPa.
After adjustment is complete, push the handle (2) downward to
lock it.
4-12. Adjusting the speed controller [7]
You can adjust the lifting and lowering speeds for the work
clamp using the knobs on the valves.
When the upper knob is tightened, the lifting speed becomes
slower. When it is loosened, the lifting speed becomes faster.
When the lower knob is tightened, the lowering speed
becomes slower. When it is loosened, the lowering speed
becomes faster.
Reference adjustments
Upper knob
Fully tighten
Valve 1
Lower knob
Fully tighten and then loosen by
8 turns
Upper knob
Fully tighten and then loosen by
5 turns
Valve 2
Lower knob
Fully tighten
You can operate the work clamp when the power is turned off
by pressing the manual buttons (1).
3975M
Upper knob
Lower knob
Valve 1
3976M
Valve 2