Location adjustment of the cap support

Page 20 highlights

Location adjustment of the cap support [5] 1~2mm 1~2mm [2] [1] [3] [4] W1432Q 2 3 1 5 1~2mm T ガタ 6 4[4 Loosen the screw [2] to move the cap support holder [3], and adjust the clearance between the cap support [1] and the needle plate base [5] to be 1 to 2 mm. Use the accessory T-shape hexagonal wrench 4 [4] for this adjustment. 18 Electronic embroidery machine

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

18
Electronic embroidery machine
■ボウシササエの位置調整
/ Location adjustment of the cap support
W1432Q
締めネジ
[2]
をゆるめてボウシササエウケ
[3]
を動かし、ボウシササエ
[1]
リイタドダイ
[5]
とのす
き間が
1
2mm
になるように調整してください。
調整には、付
T
6
カクレンチ
4[4]
を使用してください。
Loosen the screw [2] to move the cap support holder [3], and adjust the clearance between the cap
support [1] and the needle plate base [5] to be 1 to 2 mm.
Use the accessory T-shape hexagonal wrench 4 [4] for this adjustment.
[5]
[2]
[1]
[3]
[4]
1
2mm
1
2mm