Brother International BE-1204B Instruction Manual - English - Page 246
Cooling fan motor stop A Press R., main PCB CPU
View all Brother International BE-1204B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 246 highlights
Chapter 11 Error code list Code Error Measures E-D2 Power voltage upper limit error E-D3 Power voltage lower limit error (1) The voltage setting is improper. -> Set it again. (2) Press the or turn on the F/B switch on the head to either side. If the same error occurs again, the power PCB or the power supply is faulty. E-D4 E-D5 E-D6 E-D7 E-D8 E-E1 E-E2 E-E3 E-E4 E-E5 E-E6 E-E7 E-E8 E-E9 E-EA E-EB E-EC E-ED E-EE E-EF E-F1 E-F2 E-F3 E-F4 E-F5 E-F6 E-F7 Thread trimming motor overcurrent Needle bar case motor overcurrent Jump motor overcurrent The temperature of the heat sink on the drive PCB rose excessively Temperature sensor abnormal X-axis pulse motor overcurrent stop Y-axis pulse motor overcurrent stop Cooling fan motor stop A Press R. Lower shaft communication error Over-run error during interfacing to main PCB CPU Framing error during interfacing to main PCB CPU Parity error during interfacing to main PCB CPU Receiving time up error during interfacing to main PCB CPU Send/Receive inconsistent error during interfacing to main PCB CPU ACK code receiving error during interfacing to main PCB CPU Send/Receive ID code error during interfacing to main PCB CPU Send data checksum error during interfacing to main PCB CPU Data empty error during interfacing to main PCB CPU Abnormal data received in the inner-machine communication Receiving error on interface Receive time up error Request-to-waiting time up error Request-to-receive time up error Receive command error NACK code receiving error Data requested for needle position can not be returned. It is not receive command for the request one. Turn OFF the power. The possible causes for this error are, troubles of the thread trimming motor, troubles of the main PCB, and troubles of the drive PCB. Turn OFF the power. The possible causes for this error are, troubles of the needle bar case motor, troubles of the main PCB, and troubles of the drive PCB. Turn OFF the power. The possible causes for this error are troubles of the jump motor and troubles of the head PCB. Turn OFF the power and check if the fan filter has any clogging. Turn OFF the power. The possible causes for this error are troubles of the thermistor and troubles of the drive PCB. Turn OFF the power and ON once. If the same error occurs again, the pulse motor or the drive PCB is faulty. Turn OFF the power and check the fan harness. Turn OFF the power again. If the same error occurs again, the fan or the power PCB is faultly. This is not usually displayed. 11-6 BE-1204B-BC • BE-1206B-BC