disarming diagnostics, arm/disarm diagnostic chart
View all Clifford IntelliGuard 950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
The security system will ignore the input that was active when the system was armed, until the input goes away. Three seconds later the system will monitor that input normally. For example, if your vehicle has the boot open, and you arm the system, you will hear Bypass Notification chirps. Once you shut the boot, however, it is then monitored normally. disarming diagnostics Extra disarm chirps are the Tamper Alert warning. If you hear three chirps when disarming, the system was triggered in your absence. If three chirps are heard, the LED status indicator will indicate which zone was triggered when you turn the ignition on (see the Table of Zones section). The system will retain this information in its memory. Refer to the Multiple Event Total Recall section of this guide. arm/disarm diagnostic chart Action Arm Arm Chirps 2 4 Light Flashes 2 4 Arm 2 (5 sec.) 4 2 (5 sec.) 4 Arm 2 (10 sec.) 4 2 (10 sec.) 4 Disarm 3 3 Disarm 1 1 Disarm 1 (low pitch) 1 Description System armed System armed with boot or bonnet active and bypassed (zones 5 and 6) System armed with door active and bypassed (zone 4) System armed with sensor active and bypassed zones (1, 2, 3, and 8) System disarmed with tamper alert System disarmed System disarmed with transmitter low battery warning © 2004 directed electronics, inc. 17