Dacor HGPR30 Installation Instruction - 30" Pro Gas Range - Page 4
Planning the Installation
View all Dacor HGPR30 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Planning the Installation WARNING • Follow all codes and ordinances during planning/installation. Contact your local building department for details. • To avoid an electric shock hazard, the power supply must meet the specifications below. The owner shall ensure the electrical service meets requirements and that the outlet is installed by a licensed electrician. The range must be grounded per local codes, or in their absence, per the National Electrical Code, ANSI/ NFPA 70. Gas-Supply Requirements • Installation of this range must comply with local codes or, in their absence, the National Fuel Gas Code, ANSI Z223.1/NFPA 54. • Ensure the range matches the home gas service (natural gas or LP gas). • If using the range above 4000 ft. (1219 m), ensure it is equipped for high-altitude use. See the rating label (inside cover) to verify that you have the proper model. • The gas-supply pressure requirements in this table are for reference only. (See the rating label for exact specifications). Electrical Requirements • The range is comes with a 6-ft. power cord with a 3-prong grounding plug connected to the rear of the range. It must be plugged in to a dedicated, grounded 3-prong electrical outlet. • The range must receive the correct voltage/frequency/amperage from a separate, grounded circuit protected by a proper-size circuit breaker or time-delay fuse. Circuit Required Total Connected Load* 120 Vac, 60 Hz, 15 Amp. 120 Vac 60 Hz, 5.0 Amp. *These specifications are for reference only. See the rating label (back of range) for exact spec's. GAS-SUPPLY PRESSURE REQUIREMENTS* Gas Type Minimum Manifold Pressure Min. Gas-Supply Pressure** Natural Gas 5-in. Water Column 6-in. Water Column Liquid Propane (LP) 10-in. Water Column 11-in. Water Column *Gas-supply pressure for testing the regulator setting shall be at least 1 in. water column (249 Pa) above the specified manifold pressure; **Max. gas-supply pressure for all models: 1/2 psi. • The regulator is factory-installed. Use only the installed regulator. The regulator inlet receives a 3/4" gas line. The range ships with a 1/2"-to-3/4" adapter on the regulator. GAS-/ELECTRICAL-ACCESS DIMENSIONS A B 13 1/16" - 14 3/8" (33.18 - 36.51 cm) 4 5/16" (10.95 cm) Rating Label 2 Gas Inlet Power cord Gas and Power Access (panels removed to show gas connections)