Dell 341-7212 User Guide - Page 4

Monitoring System Events and Storage Devices

Page 4 highlights

Creating a RAID 1 Configuration on a SAS 5/iR Controller or on a SAS 6/iR Controller 18 Creating a New Configuration on a Dell PERC 5/i Controller or on a Dell PERC 6/i Controller 19 Understanding Virtual Disk Parameters 19 Using Auto Configuration on a Dell PERC 5/i Controller or on a Dell PERC 6/i Controller 21 Using Guided Configuration on a Dell PERC 5/i Controller or on a Dell PERC 6/i Controller 22 Using Manual Configuration on a Dell PERC 5/i Controller or on a Dell PERC 6/i Controller (RAID 0, 1, 5, and 6 23 Using Manual Configuration on a Dell PERC 5/i Controller or on a Dell PERC 6/i Controller (RAID 10 25 Adding Hotspare Disks 26 Using the Replace Member Feature and Revertible Hot Spares . . . 27 Changing Adjustable Task Rates 28 Changing Virtual Disk Properties 29 Changing a Virtual Disk Configuration 29 Adding a Disk Drive to a Configuration on a PERC 5/i Controller or on a PERC 6/i Controller 30 Changing the RAID Level of a Configuration on a PERC 5/i Controller or on a PERC 6/i Controller 30 Deleting a Virtual Disk 30 Saving a Storage Configuration to Disk 31 Clearing a Storage Configuration from a Controller 31 Adding a Saved Storage Configuration 32 5 Monitoring System Events and Storage Devices. . . 33 Monitoring System Events 33 Monitoring Controllers 33 4 Contents

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

4
Contents
Creating a RAID 1 Configuration on a SAS 5/iR Controller or
on a SAS 6/iR Controller
. . . . . . . . . . . . . . . . . . . . .
18
Creating a New Configuration on a Dell PERC 5/i Controller or
on a Dell PERC 6/i Controller
. . . . . . . . . . . . . . . . . . . . .
19
Understanding Virtual Disk Parameters
. . . . . . . . . . . . .
19
Using Auto Configuration on a Dell PERC 5/i Controller or
on a Dell PERC 6/i Controller
. . . . . . . . . . . . . . . . . . .
21
Using Guided Configuration on a Dell PERC 5/i Controller
or on a Dell PERC 6/i Controller
. . . . . . . . . . . . . . . . .
22
Using Manual Configuration on a Dell PERC 5/i Controller
or on a Dell PERC 6/i Controller (RAID 0, 1, 5, and 6)
. . . . . . .
23
Using Manual Configuration on a Dell PERC 5/i Controller
or on a Dell PERC 6/i Controller (RAID 10)
. . . . . . . . . . . .
25
Adding Hotspare Disks
. . . . . . . . . . . . . . . . . . . . . . . .
26
Using the Replace Member Feature and Revertible Hot Spares
. . .
27
Changing Adjustable Task Rates
. . . . . . . . . . . . . . . . . . .
28
Changing Virtual Disk Properties
. . . . . . . . . . . . . . . . . . .
29
Changing a Virtual Disk Configuration
. . . . . . . . . . . . . . . .
29
Adding a Disk Drive to a Configuration on a PERC 5/i
Controller or on a PERC 6/i Controller
. . . . . . . . . . . . . .
30
Changing the RAID Level of a Configuration on a PERC 5/i
Controller or on a PERC 6/i Controller
. . . . . . . . . . . . . .
30
Deleting a Virtual Disk
. . . . . . . . . . . . . . . . . . . . . . . .
30
Saving a Storage Configuration to Disk
. . . . . . . . . . . . . . . .
31
Clearing a Storage Configuration from a Controller
. . . . . . . . .
31
Adding a Saved Storage Configuration
. . . . . . . . . . . . . . . .
32
5
Monitoring System Events and Storage Devices
. . .
33
Monitoring System Events
. . . . . . . . . . . . . . . . . . . . . . .
33
Monitoring Controllers
. . . . . . . . . . . . . . . . . . . . . . . .
33