Table 7-2. Dell SAS RAID Storage Manager Messages (continued) Message Meaning Action Cannot create Virtual Disk: Invalid input parameters for creating Virtual Disk. You have entered some parameters that are not valid for the virtual disk. Be sure that all the virtual disk parameters are valid, and then retry creating the virtual disk. The drive is not in a state to perform. The physical drive does not This functionality is not supported. support this command. This Check the state of the physical might happen when you drive. send an Undo Prepare for Removal command to the wrong physical drive. Save configuration failed. The Save Configuration command failed while attempting to save the configuration to a file. Be sure that you are saving the configuration to the correct location. Be sure there is adequate free space for the file on the disk. Be sure you have write permission on the target. Reconstruction This virtual disk does not Verify that the hardware is properly on this Volume is support the Reconstruction connected and retry. not allowed! command. The system hardware is not allowing any kind of reconstruction. Fatal Error: Cannot connect to Framework! A software component of Confirm that the device driver is Dell SAS RAID Storage installed and that the system has Manager cannot establish a been rebooted. If the driver is connection to the MSM present, uninstall and re-install the framework. The Dell SAS application. RAID Storage Manager GUI is not able to communicate with the server side software component. 64 Troubleshooting