Dedicated Hot Spare %s disabled, SAS topology error: Out of route entries

Page 72 highlights

Table A-2. Event Messages (continued) Number 0x006d 0x006e 0x006f 0x0070 0x0071 0x0072 0x0073 0x0074 0x0075 0x0076 Type Fatal Info Fatal Info Warning Info Info Warning Info Info 0x0077 0x0078 0x0079 0x007a 0x007b 0x007c 0x007d 0x007e 0x007f 0x0080 0x0081 0x0082 0x0083 0x0084 0x0085 0x0086 Caution Caution Caution Caution Caution Caution Caution Caution Caution Caution Caution Caution Fatal Info Info Caution Event Text Unrecoverable medium error during rebuild on %s at %lx Corrected medium error during recovery on %s at %lx Unrecoverable medium error during recovery on %s at %lx PD removed: %s Unexpected sense: %s, CDB%s, Sense: %s State change on %s from %s to %s State change by user on %s from %s to %s Redundant path to %s broken Redundant path to %s restored Dedicated Hot Spare PD %s no longer useful due to deleted array SAS topology error: Loop detected SAS topology error: Un-addressable device SAS topology error: Multiple ports to the same SAS address SAS topology error: Expander error SAS topology error: SMP timeout SAS topology error: Out of route entries SAS topology error: Index not found SAS topology error: SMP function failed SAS topology error: SMP CRC error SAS topology error: Multiple subtractive SAS topology error: Table to table SAS topology error: Multiple paths Unable to access device %s Dedicated Hot Spare created on %s (%s) Dedicated Hot Spare %s disabled Dedicated Hot Spare %s no longer useful for all arrays 72 Events and Messages

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

72
Events and Messages
0x006d
Fatal
Unrecoverable medium error during rebuild on %s at %lx
0x006e
Info
Corrected medium error during recovery on %s at %lx
0x006f
Fatal
Unrecoverable medium error during recovery on %s at %lx
0x0070
Info
PD removed: %s
0x0071
Warning
Unexpected sense: %s, CDB%s, Sense: %s
0x0072
Info
State change on %s from %s to %s
0x0073
Info
State change by user on %s from %s to %s
0x0074
Warning
Redundant path to %s broken
0x0075
Info
Redundant path to %s restored
0x0076
Info
Dedicated Hot Spare PD %s no longer useful due to deleted
array
0x0077
Caution
SAS topology error: Loop detected
0x0078
Caution
SAS topology error: Un-addressable device
0x0079
Caution
SAS topology error: Multiple ports to the same SAS address
0x007a
Caution
SAS topology error: Expander error
0x007b
Caution
SAS topology error: SMP timeout
0x007c
Caution
SAS topology error: Out of route entries
0x007d
Caution
SAS topology error: Index not found
0x007e
Caution
SAS topology error: SMP function failed
0x007f
Caution
SAS topology error: SMP CRC error
0x0080
Caution
SAS topology error: Multiple subtractive
0x0081
Caution
SAS topology error: Table to table
0x0082
Caution
SAS topology error: Multiple paths
0x0083
Fatal
Unable to access device %s
0x0084
Info
Dedicated Hot Spare created on %s (%s)
0x0085
Info
Dedicated Hot Spare %s disabled
0x0086
Caution
Dedicated Hot Spare %s no longer useful for all arrays
Table A-2.
Event Messages
(continued)
Number
Type
Event Text