Dell PowerEdge 2200 Service Manual

Dell PowerEdge 2200 Manual

Dell PowerEdge 2200 manual content summary:

  • Dell PowerEdge 2200 | Service Manual - Page 1
    'HOOŠ3RZHU(GJHŠ6\VWHPV 6(59,&(0$18$/
  • Dell PowerEdge 2200 | Service Manual - Page 2
    . Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, and PowerEdge are registered trademarks of Dell Computer Corporation; MS-DOS and Microsoft are registered trademarks of
  • Dell PowerEdge 2200 | Service Manual - Page 3
    1-1 System Memory 1-5 Advanced Expansion Subsystem 1-6 Integrated Server Management 1-6 Video Controller 1-6 Integrated SCSI Controller 1-6 SCSI Hard-Disk Drives 1-7 SCSI Configuration Guidelines 1-7 SCSI ID Numbers 1-7 Device Termination 1-8 System Unit 1-10 System Power Supply 1-10
  • Dell PowerEdge 2200 | Service Manual - Page 4
    3-1 POST Beep Codes 3-1 System Error Messages 3-3 Chapter 4 Removing and Replacing Parts 4-1 Recommended Tools 4-1 Precautionary Measures 4-2 Computer Cover 4-3 Front Bezel 4-4 Front-Bezel Inserts 4-5 Control Panel Assembly 4-7 Drives 4-8 Externally Accessible Drives 4-9 Hard-Disk Drives
  • Dell PowerEdge 2200 | Service Manual - Page 5
    Assembly Removal 4-7 Figure 4-7. Drive Hardware 4-8 Figure 4-8. Externally Accessible Drives Removal 4-9 Figure 4-9. Drive-Mounting Rails and Extensions Removal 4-10 Figure 4-10. Hard-Disk Drive Removal 4-11 Figure 4-11. Expansion Card Removal 4-12 Figure 4-12. Power Supply Removal 4-13 vii
  • Dell PowerEdge 2200 | Service Manual - Page 6
    Descriptions 1-16 Interrupt Assignments 1-17 DREQ Line Assignments 1-18 Technical Specifications 1-19 POST Beep Codes 3-1 System Error Messages 3-3 Key Functions A-2 Main Menu Categories A-4 Boot Options Submenu Categories A-5 Advanced Menu Categories A-7 Security Menu Categories A-9 Exit
  • Dell PowerEdge 2200 | Service Manual - Page 7
    ix
  • Dell PowerEdge 2200 | Service Manual - Page 8
    addition to information provided in this manual and the User's Guide that came with the system, Dell provides the Diagnostics and Troubleshooting Guide for troubleshooting procedures and instructions on using the Dell diagnostics to test the computer system. Warnings, Cautions, and Notes Throughout
  • Dell PowerEdge 2200 | Service Manual - Page 9
    been designed for better serviceability, increased reliability, SCSI hard-disk drives, thermal and power supply monitoring, and extendeddata out (EDO) DIMMs that support ECC. The PowerEdge 2200 systems are freestanding or can be rackmounted for integrating your servers. The microprocessor(s) are
  • Dell PowerEdge 2200 | Service Manual - Page 10
    Guide (P/N 87743). When following the text in this manual, assume that the location or direction relative to the computer is as shown in Figure 1-1. back of computer left side right side front of computer Figure 1-1. Computer Orientation 1-2 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 11
    3.5-inch diskette drive diskette-drive access indicator CD-ROM drive CD-ROM drive access indicator third drive bay power button power indicator drive access indicator reset button Figure 1-2. Front-Bezel Features CAUTION: To avoid possible data or file structure corruptions, the front-bezel reset
  • Dell PowerEdge 2200 | Service Manual - Page 12
    drive CD-ROM drive third drive bay diskette controller cable power cables control panel cable SCSI cable system cooling fan front bezel internal hard-disk drive cage Figure 1-3. Front/Right Side Internal View system-board/ mounting plate assembly 1-4 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 13
    power-supply selector switch AC power input connector I/O panel connectors externally accessible drive bays (3) SCSI hard-disk drive cage SCSI cable hard-disk-drive power cables system board Figure 1-4. Back/Left Side Internal View System Memory System memory has a minimum of 32 MB of 72-bit-wide,
  • Dell PowerEdge 2200 | Service Manual - Page 14
    of DIMM configurations, see "Adding Memory" in Chapter 7 of the Dell PowerEdge 2200 Systems User's Guide. See "DIMMs" in Chapter 4 for information on removing and replacing DIMMs. Advanced Expansion Subsystem The computer system offers advanced expansion subsystems that can support a mixture of
  • Dell PowerEdge 2200 | Service Manual - Page 15
    from Dell, the default SCSI ID numbers are assigned as follows: • The computer's built-in SCSI controller is configured through the BIOS as SCSI ID 7 (the default ID number for a host adapter) if the system includes a CD-ROM or tape drive. NOTE: If only wide SCSI hard-disk drives are connected
  • Dell PowerEdge 2200 | Service Manual - Page 16
    instructions. Figure 1-5 shows an example of a SCSI termination jumper on a CD-ROM drive. CAUTION: When you install or remove a termination jumper, do not move or remove any other jumpers installed on the drives or data may be corrupted during transmission. 1-8 Dell PowerEdge 2200 Systems Service
  • Dell PowerEdge 2200 | Service Manual - Page 17
    termination jumper CD-ROM drive (end view) jumpered unjumpered Seagate 2-, 4-, and 9-GB hard-disk drives (bottom view) termination jumper termination jumper Western Digital 2-GB and 4-GB hard-disk drive (end view) Figure 1-5. SCSI Termination Jumper Examples System Overview 1-9
  • Dell PowerEdge 2200 | Service Manual - Page 18
    "standby power." Pin Assignments for the DC Power Connectors The power-supply output voltages can be measured at the back (wire side) of the connectors without disconnecting them. Figures 1-6, 1-7, and 1-8 show the wire sides of the connectors. 1-10 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 19
    its active-low state. 2 Pin 5 - PWRGOOD should measure between +4 and +5 VDC when the power supply is on and operating, to indicate that all power-supply output voltages are within ranges specified in Table 1-1. Figure 1-6. DC Power Connector P1 1234 P2, P3, P5, P6 +12 VDC (yellow) common (black
  • Dell PowerEdge 2200 | Service Manual - Page 20
    power distribution: • Power-supply connector identification • Power cable connections for diskette, tape, CD-ROM, and hard-disk drives • Power distribution to sockets and connectors on the system board P1 P4 P5 P7 P6 P3 P2 Figure 1-9. DC Power Cables 1-12 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 21
    internal hard-disk drive P6 internal hard-disk drive internal hard-disk drive Y-cable main memory sockets DIMM_D DIMM_C DIMM_B DIMM_A PROC_1 +12 VDC +5 VFP +5 VDC fuse +5 VDC +5 VDC processor core regulator FAN PANEL KYBD MOUSE +3.3 VDC core VCC (+1.8 to +3.5 VDC) PROC_2 Figure 1-10. DC Power
  • Dell PowerEdge 2200 | Service Manual - Page 22
    module (PROC_1) secondary microprocessor module (PROC_2) hard-disk drive access indicator connector (HDLED) auxiliary fan connector (AUXFAN) configuration jumpers PCI connectors (PCI4 [bottom], PCI5, and PCI6) server management connector (SVR_MGT) 1-14 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 23
    System Board Jumpers Figure 1-12. System Board Jumpers RSVD2 RSVD1 266MHZ 233MHZ PASSWD EISA VGA CARDBIOS System Overview 1-15
  • Dell PowerEdge 2200 | Service Manual - Page 24
    BIOS card Remove jumper and use EISA Configuration Utility to configure system. Install jumper to enable integrated video controller. Install jumper to boot system from BIOS expansion card. Remove jumper to allow normal boot operation from BIOS. 1-16 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 25
    parallel port IRQ6 Generated by super I/O controller to indicate that diskette or tape drive requires service IRQ7 Generated by super I/O controller to indicate that device connected to parallel port requires service IRQ8 Generated by keyboard controller for each tick of RTC IRQ9 Available for
  • Dell PowerEdge 2200 | Service Manual - Page 26
    DREQ1 Available DREQ2 Generated by super I/O controller to initiate DMA cycle for attached diskette drive DREQ3 Available DREQ4 Generated by bus controller chip to activate second DMA controller DREQ5 Available DREQ6 Available DREQ7 Available 1-18 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 27
    Specifications Table 1-5. Technical Specifications external processor speed) Diskette/communications ports 24 MHz from the system clock SCSI channel 40 MHz Memory Architecture 72-bit (64 data bits plus 8 ECC bits), noninterleaved, buffered, EDO-type memory DIMM sockets
  • Dell PowerEdge 2200 | Service Manual - Page 28
    . . . . one 68-pin Ultra/Wide (fast-20) connector Diskette drive . . . . . 34-pin connector Controls and Indicators Reset control push button Power control push button Power indicator green LED Diskette-drive access indicator green LED 1-20 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 29
    Hard-disk drive access indicator green LED CD-ROM drive access indicator green LED Video Video type ATI mach64 (264VT) PCI video controller with integrated VGA connector Video memory (standard 1 MB (not upgradable) Power DC power supply noncondensing) Maximum vibration: Operating 0.25 G at
  • Dell PowerEdge 2200 | Service Manual - Page 30
    (continued) Maximum shock: Operating half-sine wave form: 50 G for 2 ms Storage half-sine wave form: 110 G for 2 ms; square wave form: 27 G for 15 ms Altitude: Operating 16 to 3048 m (-50 to 10,000 ft) Storage 16 to 10,600 m (-50 to 35,000 ft) z 1-22 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 31
    or indicate the appropriate troubleshooting procedure to use. After the user describes the problem, follow these steps: 1. Ask the user to back up any data on the hard-disk drive if the system's condition permits. Appendix C, "Maintaining the System," in the User's Guide provides information about
  • Dell PowerEdge 2200 | Service Manual - Page 32
    or improper settings. For proper settings of the video monitor controls, see the documentation for the monitor. 8. Inspect the keyboard to ensure that no keys are sticking. If one or more keys are sticking, it may be necessary to replace the keyboard. 2-2 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 33
    . To observe problem indications during the boot routine, follow these steps: 1. If the system is off, turn on all peripherals and the computer. Insert the Dell Server Assistant CD into the CD-ROM drive. Press the reset button or to reboot the system. 2. Check the power supply fan
  • Dell PowerEdge 2200 | Service Manual - Page 34
    . If either of these indicators fails to light up during the boot routine, troubleshoot the diskette drive or hard-disk drive subsystem, as appropriate. 5. Observe the monitor screen for the Dell Server Assistant main menu. Does the menu appear? Yes. See "Running the System Diagnostics" found later
  • Dell PowerEdge 2200 | Service Manual - Page 35
    Configuration Utility," in the User's Guide or "Interrupt Assignments" and "DMA Channel Assignments" in Chapter 1. Running the System Diagnostics The system diagnostics (included on the Dell Server Assistant CD) contains tests that aid in troubleshooting all major components of the computer system
  • Dell PowerEdge 2200 | Service Manual - Page 36
    the source of the problem or leads to the proper troubleshooting steps for determining the source of the problem, call Dell for technical assistance. For instructions, see the chapter titled, "Getting Help," in the Diagnostics and Troubleshooting Guide. 2-6 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 37
    diagnostics to assist in troubleshooting the problem. Beep Code 1-2 1-2-2-3 1-3-1-1 Table 3-1. POST Beep Codes Error Probable Causes Invalid expansion-card ROM checksum Improperly seated expansion card or the system needs rebooting. Invalid BIOS ROM check- Corrupted BIOS firmware or sum
  • Dell PowerEdge 2200 | Service Manual - Page 38
    Defective system board. Keyboard controller error Defective DIMMs or system board. Reseat the DIMMs or replace the system board. Gate A20 failure Defective system board. 3-2 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 39
    to download embedded server management firmware. Download of ESM firmware timed out. Expansion ROM not initialized Incorrect drive A type - Run Setup Incorrect drive B type - Run Setup Invalid CPU speed detected Check jumpers The BIOS detected a resource conflict while configuring a Plug
  • Dell PowerEdge 2200 | Service Manual - Page 40
    BIOS detected a resource conflict while configuring a Plug and Play ISA or PCI expansion card. See "Eliminating Resource Conflicts" in Chapter 2. Stuck key A cable may be loose, Defective keyboard or or the keyboard may be keyboard cable. faulty. 3-4 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 41
    Module" in Chapter 4. Warning: System fan is not functioning The cooling-fan power cable is disconnected, or the cooling fan is faulty. Ensure that the fan is connected to the FAN connector on the system board. If the problem persists, the fan must be replaced. Beep Codes and Error Messages 3-5
  • Dell PowerEdge 2200 | Service Manual - Page 42
    3-6 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 43
    You have performed the steps in "Precautionary Measures" found later in this chapter. • You have removed the computer cover. • You can replace or reinstall a part by performing the removal procedure in reverse order unless additional information is provided. Recommended Tools Most of the procedures
  • Dell PowerEdge 2200 | Service Manual - Page 44
    grounding strap, and clip it to any unpainted metal sur- face on the computer chassis. If a wrist grounding strap is not available, touch any unpainted metal surface on the back of the computer chassis to discharge any static charge from your body. 4-2 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 45
    Computer Cover Removal 1. Remove the four screws along the back edge of the cover. Use the key provided with the system to remove the special keylock screw if it is installed in one of the cover-mounting screw locations. key keylock screw Figure 4-2. Security Keylock Removing and Replacing Parts
  • Dell PowerEdge 2200 | Service Manual - Page 46
    alignment holes (5) alignment pins (5) Figure 4-3. Front Bezel Removal 1. Remove the computer cover. 2. Pry the front bezel loose with your finger tips, and remove the computer chassis equal on all sides to prevent damage to the bezel alignment pins. 4-4 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 47
    of the insert in place under its latch; then press the other end into place until the tab snaps under the latch. Removing and Replacing Parts 4-5
  • Dell PowerEdge 2200 | Service Manual - Page 48
    the retaining screw at the right end of the metal insert (see Fig- ure 4-5). 3. Pivot the metal insert out and slide it to the right. 4-6 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 49
    screw control panel assembly right side of computer chassis tabs (2) Figure 4-6. Control-Panel Assembly the system board on the right side of the computer chassis. 2. Remove the screw holding the control panel assembly to the front of the computer chassis. 3. Lift the control panel assembly out
  • Dell PowerEdge 2200 | Service Manual - Page 50
    diskette drive interface connector (FLOPPY) SCSI connector (SCSI) 3.5-inch diskette drive CD-ROM drive DC power cables SCSI interface cable Figure 4-7. Drive Hardware lower externally accessible drive bay (optional drive) SCSI hard-disk drives 4-8 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 51
    All externally accessible drives have drive-mounting rails. The 3.5-inch drives also have drive-mounting extensions between the drive and the drive-mounting rails. To remove a drive assembly from one of the externally accessible drive bays, follow these steps: 1. Disconnect the DC power cable and
  • Dell PowerEdge 2200 | Service Manual - Page 52
    to 68-pin adapter drive-mounting extensions drive-release tabs Figure 4-9. Drive-Mounting Rails and Extensions Removal When you reinstall a SCSI drive, set the SCSI address jumpers and the SCSI bus termination jumpers to the settings you recorded. 4-10 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 53
    screws (4) The hard-disk drives are mounted inside a hard-disk drive bracket. The harddisk drive bracket must be removed before a hard-disk drive can be removed. To remove a hard-disk drive, follow these steps: 1. Carefully lay the computer on its right side. 2. Disconnect the DC power cable and
  • Dell PowerEdge 2200 | Service Manual - Page 54
    screw expansion card Figure 4-11. Expansion Card Removal card-guide slots (inside front of computer) 1. Carefully lay the computer on its right side. 2. Disconnect any cables attached to , and carefully remove it from the expansion-card connector. 4-12 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 55
    and the hard-disk drives (see Figure 4-7). Be sure to record the connector number and plug location for each power cable. 3. Remove the four power-supply mounting screws. 4. Slide the power supply forward about an inch to clear the retaining tabs; then lift it out of the computer. When you reinstall
  • Dell PowerEdge 2200 | Service Manual - Page 56
    Carefully lay the computer on its right part-way into the barrel.) Align the mounting holes in the system cooling fan with the holes in the back wall of the chassis. Insert each push-fastener completely; then push in the plunger to lock the fastener. 4-14 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 57
    ) primary microprocessor module (PROC_1) secondary microprocessor module (PROC_2) hard-disk drive access indicator connector (HDLED) auxiliary fan connector (AUXFAN) configuration jumpers PCI connectors (PCI4 [bottom], PCI5, and PCI6) server management connector (SVR_MGT) DIMMs NOTE: Use care when
  • Dell PowerEdge 2200 | Service Manual - Page 58
    outer edges of the DIMM with your thumbs while pulling up on the securing clips until they lock around the ends of the DIMM. 4-16 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 59
    cables from their connectors at the back of the computer. Be sure to record where each cable is attached installed, go to step 4. Otherwise, lay the computer on its right side so you can access the expansion remove any expansion cards; then place the computer in an upright position. 4. Remove the
  • Dell PowerEdge 2200 | Service Manual - Page 60
    operations. Be sure it has had sufficient time to cool before touching it. a. Remove the two screws securing the microprocessor module (see Figure 4-19). 4-18 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 61
    a Microprocessor Module From a Retention Bracket c. Press inwards on the microprocessor-module retention latches until they snap into a retracted position (see Figure 4-20). Removing and Replacing Parts 4-19
  • Dell PowerEdge 2200 | Service Manual - Page 62
    Configuration Utility to reconfigure the system. Run the system diagnostics to verify that the new microprocessor is operating correctly. If installing a second microprocessor module, remove the terminator card (see the next subsection, "Terminator Card"). 4-20 Dell PowerEdge 2200 Systems Service
  • Dell PowerEdge 2200 | Service Manual - Page 63
    up. 3. Remove the terminator card. Hold the card by its edges, and lift the card straight up from the microprocessor retention bracket. Removing and Replacing Parts 4-21
  • Dell PowerEdge 2200 | Service Manual - Page 64
    retention bracket from the system board/mounting plate assembly. clips (2 per bracket) microprocessor retention bracket screws (4 per bracket) Figure 4-24. Retention Bracket Screw Removal 4-22 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 65
    batteries according to the manufacturer's instructions. To remove the system Setup screens (see Appendix A). 2. Lay the computer on its right side. 3. Remove any expansion configuration information with the copy of the system configuration settings you made in step 1. Restore any system configuration
  • Dell PowerEdge 2200 | Service Manual - Page 66
    5. Remove the microprocessor retention brackets. 6. Slide the system board toward the front of the computer to disengage the system-board mounting hooks. 7. Lift the system board out of the system- jumper settings on the new system board are correct. 4-24 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 67
    program, which is used to change the system configuration information stored in NVRAM on the system board. To enter the System Setup program, press during the power-on self-tests. If you wait too long, the operating system begins to load into memory and you cannot enter the System Setup program
  • Dell PowerEdge 2200 | Service Manual - Page 68
    for the field Loads the default configuration values for this menu Loads the default configuration values for all setup items Loads the previous configuration values for this menu Executes the selected command or displays a submenu Refreshes the screen A-2 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 69
    Menu configuration options and system data box help box title box Dell System PowerEdge 2200 Setup Main Advanced Security Exit Time: [5:01:96] Date: [June 04, 1997] Diskette Drive A: [1.44 MB, 3.5 inch] Diskette Drive B: [Not Installed] Fast Video BIOS: [On and Cached] Memory Cache
  • Dell PowerEdge 2200 | Service Manual - Page 70
    as extended memory. Video Memory Displays amount of video memory installed on the system board. Service Tag Displays system's five-character service tag number. Asset Tag Displays the asset tag number (up to ten characters) if one is assigned. A-4 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 71
    Submenu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Boot Options Boot Sequence: [A: then C:] SETUP Prompt: [Enabled] POST Errors: [Enabled] Diskette Drive Check: [Enabled] Reset Button: [Enabled] BIOS Version AXX Item Specific Help Determines the order of drives from
  • Dell PowerEdge 2200 | Service Manual - Page 72
    ] [1.4] [Enabled] BIOS Version AXX Item Specific Help Configures the system's built-in serial port. F1 Help ESC Exit Select Item Select Menu -/+ Change Values Enter Select Sub-Menu F9 Setup Defaults F10 Previous Values Figure A-3. Advanced Menu A-6 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 73
    built-in PCI SCSI controller and determines if it is scanned as a boot drive. PCI Scan Sequence Determines the sequence the PCI devices are scanned. Use MP Specifications Configures the Multiprocessor Specification level. The default is 1.4; however, some operating systems use 1.1. PS/2 Mouse
  • Dell PowerEdge 2200 | Service Manual - Page 74
    access to the Setup menu. The supervisor password must be enabled before the user password can be set. F1 Help ESC Exit Select Item Select Menu -/+ Change Values Enter Select Sub-Menu F9 Setup Defaults F10 Previous Values Figure A-4. Security Menu A-8 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 75
    Supervisor Password Feature" in Chapter 4 of the Dell PowerEdge 2200 Systems User's Guide. User Password Is Displays current status of user's password (enabled or disabled). See "Using the User Password Feature" in Chapter 4 of the User's Guide. Set Supervisor Password Displays a dialog box to
  • Dell PowerEdge 2200 | Service Manual - Page 76
    all changes made in the Setup program to CMOS, exits the Setup program, and then reboots the computer. F1 Help ESC Exit Select Item Select Menu -/+ Change Values Enter Select Sub-Menu Figure A-5. Exit Menu F9 Setup Defaults F10 Previous Values A-10 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 77
    Function Save Changes & Exit Saves the changes you have made before you exit the System Setup program. The next time you boot up your system, the BIOS configures your system according to the selections stored in CMOS. Exit Without Saving Changes Exits the System Setup program without saving any
  • Dell PowerEdge 2200 | Service Manual - Page 78
    A-12 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 79
    15 BATTERY socket, 4-15 beep codes about, 3-1 list of, 3-1 bezel removal, 4-4 boot routine observing when troubleshooting, 2-3 bracket hard-disk drive, removal, 4-11 C cables, DC power, 1-12 CD-ROM drive access indicator location, 1-3 location, 1-4, 4-8 removal, 4-9 computer back/left side internal
  • Dell PowerEdge 2200 | Service Manual - Page 80
    , front-bezel, 4-5 integrated SCSI controller, 1-6 server management, 1-6 video controller, 1-6 interrupt assignments list of, 1-17 J jumpers descriptions, 1-16 list of, 1-16 location on system board, 1-15 JVGA connector, 4-15 K KYBD connector, 4-15 2 Dell PowerEdge 2200 Systems Service Manual
  • Dell PowerEdge 2200 | Service Manual - Page 81
    , 1-6 POST beep codes, 3-1 power button, 1-3 POWER connector, 4-15 power indicator, 1-3 power supply about, 1-10 configuration guidelines, 1-7 SCSI connector, 4-15 SCSI controller, integrated, 1-6 SCSI devices ID numbers, 1-7 SCSI hard-disk drives. See drives SERIAL connector, 4-15 specifications
  • Dell PowerEdge 2200 | Service Manual - Page 82
    boot routine, observing, 2-3 external visual inspection, 2-2 initial procedures, 2-1 initial user contact, 2-1 internal visual inspection, 2-4 U user contact, initial, 2-1 V video controller, integrated, 1-6 visual inspection external, 2-2 internal, 2-4 4 Dell PowerEdge 2200 Systems Service Manual
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

’HOO
±
3RZHU(GJH
±
²²³³±6\VWHPV
6(59,&(±0$18$/