A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 (SCSI) host adapter with RAID control capabilities. It provides reliable fault-tolerant disk subsystem management and is an ideal RAID solution for internal storage in Dell's PowerEdge enterprise systems. The RAID controller offers a cost-effective way to implement RAID in a server. Dell is currently offering its fourth generation of RAID controllers, the PERC 4e family, supporting the industry standard Ultra320 SCSI storage interconnect. PERC 4e RAID controllers support the PCI-Express host interconnects for maximum bandwidth connectivity & expandability. The PERC 4e family of controllers includes the PERC 4e/SI and PERC 4e/DI for RAID On Motherboard solutions and the PERC 4e/DC add-in HBA. The following matrix describes the benefits of each solution. Previous generations of PERC have included the PERC 2, PERC 3 and PERC 4 families. The following PERC solutions support the PowerVault 220S and 221S External SCSI Storage solution: • Table 3-1: PERC Solution supported by PV22xS Maximum Speed 80 MB/s 160 MB/s 320 MB/s Card PERC 2/DC PERC 2/QC 39160 HBA PERC 3/DC PERC 3/QC PE 2600 ROMB (PERC 4/Di on this server) PE 1750 ROMB (PERC 4/Di on this server) PERC 4/SC PE 2800 ROMB (PERC 4e/Di on this server) PE 2850 ROMB (PERC 4e/Di on this server) PE 6800 ROMB (PERC 4e/Di on this server) PE6850 ROMB (PERC 4e/Di on this server) PERC 4/DC (PCI, dual channel U320 RAID add-in HBA) PERC 4e/DC (PCI-Express, dual channel U320 RAID addin HBA) SCSI Cabling HBA and PERC controllers support a low-voltage differential (LVD) SCSI bus. LVD enables cables up to 12 meters long. Throughput on each SCSI channel can be as high as 320 MB/sec. PAGE 15 11/17/2005

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS
VER A02
PAGE 15
11/17/2005
(SCSI) host adapter with RAID control capabilities. It provides reliable fault-tolerant disk
subsystem management and is an ideal RAID solution for internal storage in Dell's
PowerEdge enterprise systems. The RAID controller offers a cost-effective way to
implement RAID in a server.
Dell is currently offering its fourth generation of RAID controllers, the PERC 4e family,
supporting the industry standard Ultra320 SCSI storage interconnect.
PERC 4e RAID
controllers support the PCI-Express host interconnects for maximum bandwidth
connectivity & expandability.
The PERC 4e family of controllers includes the PERC 4e/SI
and PERC 4e/DI for RAID On Motherboard solutions and the PERC 4e/DC add-in HBA.
The following matrix describes the benefits of each solution.
Previous generations of PERC have included the PERC 2, PERC 3 and PERC 4 families.
The following PERC solutions support the PowerVault 220S and 221S External SCSI
Storage solution:
Table
3-1: PERC Solution supported by PV22xS
Maximum
Speed
Card
80 MB/s
PERC 2/DC
PERC 2/QC
160 MB/s
39160 HBA
PERC 3/DC
PERC 3/QC
320 MB/s
PE 2600 ROMB (PERC 4/Di on this server)
PE 1750 ROMB (PERC 4/Di on this server)
PERC 4/SC
PE 2800 ROMB (PERC 4e/Di on this server)
PE 2850 ROMB (PERC 4e/Di on this server)
PE 6800 ROMB (PERC 4e/Di on this server)
PE6850 ROMB (PERC 4e/Di on this server)
PERC 4/DC (PCI, dual channel U320 RAID add-in HBA)
PERC 4e/DC (PCI-Express, dual channel U320 RAID add-
in HBA)
SCSI Cabling
HBA and PERC controllers support a low-voltage differential (LVD) SCSI bus. LVD
enables cables up to 12 meters long. Throughput on each SCSI channel can be as high