Dell PowerVault 221S Optimizing Dell SCSI Solutions - Page 26

Cable Connector, Controller Connector

Page 26 highlights

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS Cable Connector VER A02 Controller Connector P-type connector - Male P-type connector - Female VHDCI-type connector - Male VHDCI-type connector - Female • Figure 4-7 External SCSI Connector PV22xS Configuration Topology and Application Attributes PV22xS provides different configuration topologies, which may impact the storage solution for an application. All PV22xS configuration modes have various benefits for application attributes and are summarized as depicted in Table 4-1 and Table 4-2: • Table 4-1: PV22xS Configuration Topologies Vs Application Attributs Application Attributes Joined PV22xS Configuration Topologies Split Cluster Reliability Default Default Default Relatively better than Joined topology - Availability Default depending on RAID High level (see Table 4-2 for details) Serviceability All interconnect components are Field Replaceable units Redundancy Performance Data Protection Scalability Cost • Not on SCSI Path • Management capabilities with both ZEMMs • Not on SCSI Path • Management capabilities with both ZEMMs Depends on HDD and ZEMM technology - U160/U320 Provides both data and management Relatively lower performance due to RAID controller configuration requirements Default Default Default Maximum Could be lower with Single ZEMM and non-redundant PSU Minimum (for a given topology) Same as Joined, but one HDD less Requires two ZEMMs, but can be lower with non-redundant PSU PAGE 26 11/17/2005

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS
VER A02
PAGE 26
11/17/2005
Cable Connector
Controller Connector
P-type connector – Male
P-type connector – Female
VHDCI-type connector – Male
VHDCI-type connector – Female
Figure
4-7 External SCSI Connector
PV22xS Configuration Topology and Application Attributes
PV22xS provides different configuration topologies, which may impact the storage solution
for an application. All PV22xS configuration modes have various benefits for application
attributes and are summarized as depicted in Table
4-1 and Table
4-2:
Table
4-1: PV22xS Configuration Topologies Vs Application Attributs
PV22xS Configuration Topologies
Application
Attributes
Joined
Split
Cluster
Reliability
Default
Default
Default
Availability
Default
Relatively better than
Joined topology –
depending on RAID
level (see Table
4-2 for
details)
High
Serviceability
All interconnect components are Field Replaceable units
Redundancy
Not on SCSI
Path
Management
capabilities with
both ZEMMs
Not on SCSI Path
Management
capabilities with
both ZEMMs
Provides both data
and management
Performance
Depends on HDD and ZEMM technology –
U160/U320
Relatively lower
performance due to
RAID controller
configuration
requirements
Data
Protection
Default
Default
Default
Scalability
Maximum
Minimum (for a given
topology)
Same as Joined, but
one HDD less
Cost
Could be lower with
Single ZEMM and
non-redundant PSU
Requires two ZEMMs, but can be lower with
non-redundant PSU