Step 8: (Optional) Set Up In-Band Management
View all Dell PowerVault MD3200i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Step 8: (Optional) Set Up In-Band Management Out-of-band management (see "Step 1: Discover the Storage Array (Out-ofband Management Only)" on page 54) is the recommended method for managing the storage array. However, to optionally set up in-band management, use the steps shown below. The default iSCSI host port IPv4 addresses are shown below for reference: Controller 0, Port 0: IP: 192.168.130.101 Controller 0, Port 1: IP: 192.168.131.101 Controller 0, Port 0: IP: 192.168.132.101 Controller 0, Port 1: IP: 192.168.133.101 Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP: 192.168.131.102 Controller 1, Port 0: IP: 192.168.132.102 Controller 1, Port 1: IP: 192.168.133.102 NOTE: The management station you are using must be configured for network communication to the same IP subnet as the MD32xx host ports. 1 Establish an iSCSI session to the MD3200i RAID storage array. 2 Restart the SMagent service. 3 Launch MDSM. If this is the first storage array to be set up for management, the Add New Storage Array window appears. Otherwise, click New. 4 Select Manual and click OK. 5 Select In-band management and enter the host server name(s) or IP address(es) of the host server that is running the MD Storage Manager software. 6 Click Add. In-band management should now be successfully configured. 72 Appendix-Manual Configuration