Dell PowerVault MD3200i Deployment Guide - Page 72

Step 8: (Optional) Set Up In-Band Management

Page 72 highlights

Step 8: (Optional) Set Up In-Band Management Out-of-band management (see "Step 1: Discover the Storage Array (Out-ofband Management Only)" on page 54) is the recommended method for managing the storage array. However, to optionally set up in-band management, use the steps shown below. The default iSCSI host port IPv4 addresses are shown below for reference: Controller 0, Port 0: IP: 192.168.130.101 Controller 0, Port 1: IP: 192.168.131.101 Controller 0, Port 0: IP: 192.168.132.101 Controller 0, Port 1: IP: 192.168.133.101 Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP: 192.168.131.102 Controller 1, Port 0: IP: 192.168.132.102 Controller 1, Port 1: IP: 192.168.133.102 NOTE: The management station you are using must be configured for network communication to the same IP subnet as the MD32xx host ports. 1 Establish an iSCSI session to the MD3200i RAID storage array. 2 Restart the SMagent service. 3 Launch MDSM. If this is the first storage array to be set up for management, the Add New Storage Array window appears. Otherwise, click New. 4 Select Manual and click OK. 5 Select In-band management and enter the host server name(s) or IP address(es) of the host server that is running the MD Storage Manager software. 6 Click Add. In-band management should now be successfully configured. 72 Appendix-Manual Configuration

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

72
Appendix—Manual Configuration
Step 8: (Optional) Set Up In-Band Management
Out-of-band management (see "Step 1: Discover the Storage Array (Out-of-
band Management Only)" on page 54) is the recommended method for
managing the storage array. However, to optionally set up in-band
management, use the steps shown below.
The default iSCSI host port IPv4 addresses are shown below for reference:
Controller 0, Port 0: IP: 192.168.130.101 Controller 0, Port 1: IP:
192.168.131.101
Controller 0, Port 0: IP: 192.168.132.101 Controller 0, Port 1: IP:
192.168.133.101
Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP:
192.168.131.102
Controller 1, Port 0: IP: 192.168.132.102 Controller 1, Port 1: IP:
192.168.133.102
NOTE:
The management station you are using must be configured for network
communication to the same IP subnet as the MD32xx host ports.
1
Establish an iSCSI session to the MD3200i RAID storage array.
2
Restart the
SMagent
service.
3
Launch MDSM.
If this is the first storage array to be set up for management, the
Add New
Storage Array
window appears. Otherwise, click
New
.
4
Select
Manual
and click
OK
.
5
Select In-band management and enter the host server name(s) or IP
address(es) of the host server that is running the MD Storage Manager
software.
6
Click
Add
.
In-band management should now be successfully configured.