Dewalt D25960K Instruction Manual - Page 25

Demolition Hammer D25960, D25961

Page 25 highlights

DEMOLITION HAMMER D25960, D25961 ENGLISH Congratulations! You have chosen a DEWALT power tool. Years of experience, thorough product development and innovation make DEWALT one of the most reliable partners for professional power tool users. Technical Data Voltage U.K. & Ireland only Type Frequency Power input Impact rate Impact energy (EPTA 05/2009) Tool holder Chisel positions Weight D25960 D25961 V 230 230 V 230/115 230/115 1 1 Hz 50 50 W 1600 1600 min-1 1450 1450 J 35 35 28 mm Hex 30 mm Hex 1 1 kg 18.4 16.9 LPA (sound pressure) dB(A) 91 91 KPA (sound pressure uncertainty) dB(A) 3.0 3.0 LWA (sound power) dB(A) 102 102 KWA (sound pressure uncertainty) dB(A) 3.0 3.0 Vibration total values (triax vector sum) determined according to EN 60745: Chiselling Vibration emission value ah,Cheq hand position: one handle on main handle and one hand on side handle = m/s² 6.8 6.8 both hands on main handle = m/s² 4.5 4.5 Uncertainty K = m/s² 1.5 1.5 The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure. WARNING: The declared vibration emission level represents the main applications of the tool. However if the tool is used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level over the total working period. An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep the hands warm, organisation of work patterns. Fuses: Europe U.K. & Ireland 230 V tools 230 V tools 10 Amperes, mains 13 Amperes, in plugs 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

ENGLISH
23
DEMOLITION HAMMER D25960, D25961
Congratulations!
You have chosen a D
E
WALT power tool. Years of experience, thorough product development and innovation
make D
E
WALT one of the most reliable partners for professional power tool users.
Technical Data
D25960
D25961
Voltage
V
230
230
U.K. & Ireland only
V
230/115
230/115
Type
1
1
Frequency
Hz
50
50
Power input
W
1600
1600
Impact rate
min
-1
1450
1450
Impact energy (EPTA 05/2009)
J
35
35
Tool holder
28 mm Hex
30 mm Hex
Chisel positions
1
1
Weight
kg
18.4
16.9
L
PA
(sound pressure)
dB(A)
91
91
K
PA
(sound pressure uncertainty)
dB(A)
3.0
3.0
L
WA
(sound power)
dB(A)
102
102
K
WA
(sound pressure uncertainty)
dB(A)
3.0
3.0
Vibration total values (triax vector sum) determined according to EN 60745:
Chiselling
Vibration emission value a
h,Cheq
hand position:
one handle on main handle
and one hand on side handle
=
m/s²
6.8
6.8
both hands on main handle =
m/s²
4.5
4.5
Uncertainty K =
m/s²
1.5
1.5
The vibration emission level given in this information
sheet has been measured in accordance with a
standardised test given in EN 60745 and may be
used to compare one tool with another. It may be
used for a preliminary assessment of exposure.
WARNING:
The declared vibration
emission level represents the main
applications of the tool. However if the
tool is used for different applications,
with different accessories or poorly
maintained, the vibration emission may
differ. This may significantly increase the
exposure level over the total working
period.
An estimation of the level of exposure to
vibration should also take into account
the times when the tool is switched off
or when it is running but not actually
doing the job. This may significantly
reduce the exposure level over the total
working period.
Identify additional safety measures to
protect the operator from the effects of
vibration such as: maintain the tool and
the accessories, keep the hands warm,
organisation of work patterns.
Fuses:
Europe
230 V tools
10 Amperes, mains
U.K. & Ireland
230 V tools
13 Amperes, in plugs