Adjust Low Settings on Surface, Check Ignition on Surface

Page 17 highlights

30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS 9.3 Check Ignition on Surface Burners Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power. To check for proper lighting: 1. Push in and turn a surface burner knob to the sparking position. All electronic surface ignitors will spark at the same time. Only the burner you are turning on will ignite. 2. The surface burner should light once the flow of gas reached the surface burner. Each burner should light within four (4) seconds in normal operation after air has been purged from supply lines. Visually check that burner has lit. 3. Once the burner lights, the control knob should be rotated out of the LITE position. Turn on each of the surface burners and check to see that they light properly and that the flames are even. Adjust settings if necessary. 9.4 Adjust Low Settings on Surface Burners To adjust the low setting of surface burners: 1. Push in and turn control to LITE until burner ignites. 2. Quickly turn knob to LOWEST POSITION. 3. If burner goes out, reset control to OFF. 4. Remove the surface burner control knob and decorative ring. 5. Insert a thin-bladed screwdriver into the hollow valve stem and engage the slotted screw inside. Flame size can be increased or decreased by turning the screw. Figure 30: Turn to adjust surface flame 6. Adjust flame until you can quickly turn knob from the sparking position to the lowest flame position without extinguishing the flame. Flame should be as small as possible without going out. Notes: • Air mixture adjustment is not required on surface burners. • Some models have two flames on each burner. The center flame on these burners is not adjustable. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

17
30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
9.4
Adjust Low Settings on Surface
Burners
To adjust the low setting of surface burners:
1.
Push in and turn control to LITE until burner ignites.
2.
Quickly turn knob to LOWEST POSITION.
3.
If burner goes out, reset control to OFF.
4.
Remove the surface burner control knob and
decorative ring.
5.
Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size
can be increased or decreased by turning the screw.
6.
Adjust flame until you can quickly turn knob from the
sparking position to the lowest flame position without
extinguishing the flame. Flame should be as small as
possible without going out.
Notes:
Air mixture adjustment is not required on surface
burners.
Some models have two flames on each burner. The
center flame on these burners is not adjustable.
9.3
Check Ignition on Surface
Burners
Operation of electric igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to
electric power. To check for proper lighting:
1.
Push in and turn a surface burner knob to the
sparking position. All electronic surface ignitors will
spark at the same time. Only the burner you are
turning on will ignite.
2.
The surface burner should light once the flow of gas
reached the surface burner. Each burner should light
within four (4) seconds in normal operation after air
has been purged from supply lines. Visually check
that burner has lit.
3.
Once the burner lights, the control knob should be
rotated out of the LITE position.
Turn on each of the surface burners and check to see
that they light properly and that the flames are even.
Adjust settings if necessary.
Figure 30: Turn to adjust surface flame