Fluke 116 CAL Product Manual - Page 8

Features, Table 1. Features, Switch, Position, Measurement Function

Page 8 highlights

True-rms Multimeter Features Features Table 1 is a list of the features for each Meter. Table 1. Features Switch Position Measurement Function 110 113 114 115 116 117 OFF The Meter is turned off.     x Automatically selects ac or dc volts based on the sensed input with a low impedance input.   e AC voltage from 0.06 V to 600 V. Frequency from 5 Hz to 100 kHz.         D DC voltage from 0.001 V to 600 V.      l AC voltage from 6.0 to 600 mV, dc-coupled. DC voltage from 0.1 to 600 mV.      Ω s k CHEK Ohms from 0.1 Ω to 40 MΩ. Ohms from 0.1 Ω to 60 kΩ. Continuity beeper turns on at 250 Ω. LoZ low impedance measurement function to simultaneously test for voltage or continuity.            R Diode Test. Displays OL above 2.0 V.     S Farads from 1 nF to 9999 μF.     AC current from 0.1 A to 10 A (>10 to 20 A, 30 seconds j on, 10 minutes off). >10.00 A display flashes. >20 A, OL is displayed. DC-coupled. Frequency from 45 Hz to 5 kHz.   DC current from 0.001 A to 10 A (>10 A to 20 A, I 30 seconds on, 10 minutes off). >10.00 A display flashes. >20 A, OL is displayed.   $ DC current from 0.1 to 600 μA. AC current from 6.0 to 600 μA. DC-coupled.  y Temperature from -40 °C to 400 °C (-40 °F to 752 °F) with K-type thermocouple  w Non-contact sensing of ac voltage.  Note: All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ, AC mV and AC amps are dc-coupled. MyFlukeStore Shop for Fluke products online at: www. 5 .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

True-rms Multimeter
Features
Features
Table 1 is a list of the features for each Meter.
Table 1. Features
Switch
Position
Measurement Function
110
113
114
115
116
117
OFF
The Meter is turned off.
x
Automatically selects ac or dc volts based on the sensed
input with a low impedance input.
e
AC voltage from 0.06 V to 600 V.
Frequency from 5 Hz to 100 kHz.
D
DC voltage from 0.001 V to 600 V.
l
AC voltage from 6.0 to 600 mV, dc-coupled.
DC voltage from 0.1 to 600 mV.
Ω
Ohms from 0.1
Ω
to 40 M
Ω
.
Ohms from 0.1
Ω
to 60 k
Ω
.
s
Continuity beeper turns on at <20
Ω
and turns off at
>250
Ω
.
k
CHEK
LoZ low impedance measurement function to
simultaneously test for voltage or continuity.
R
Diode Test. Displays
OL
above 2.0 V.
S
Farads from 1 nF to 9999
μ
F.
j
AC current from 0.1 A to 10 A (>10 to 20 A, 30 seconds
on, 10 minutes off). >10.00 A display flashes. >20 A,
OL
is displayed. DC-coupled
.
Frequency from 45 Hz to 5 kHz.
I
DC current from 0.001 A to 10 A (>10 A to 20 A,
30 seconds on, 10 minutes off). >10.00 A display
flashes. >20 A,
OL
is displayed
.
$
DC current from 0.1 to 600
μ
A. AC current from 6.0 to
600
μ
A. DC-coupled.
y
Temperature from -40 °C to 400 °C (-40 °F to 752 °F)
with K-type thermocouple
w
Non-contact sensing of ac voltage.
Note:
All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ, AC mV and
AC amps are dc-coupled.