Gateway 9210 Gateway 9210 Server User Guide - Page 87

Environmental specifications, Additional specifications

Page 87 highlights

Environmental specifications The following specifications identify maximum environmental conditions. At no time should the server run under conditions which violate these specifications. Variable Temperature Humidity Operating shock Package shock ESD Requirements Operating: 41° to 95°F (5° to 35°C) Maximum rate of change: 18°F (10°C) per hour Non-operating: -40° to 158°F (-40° to 70°C) Non-operating: 95% relative (non-condensing) at 80° F (30° C) No errors with a half sine wave shock of @ G (with 11 millisecond duration) Operations after a 30-inch (76.2-cm) fall. Cosmetic damage may be present (chassis weight 30 lbs/13.6 kg) +/- 15 kV per Intel environmental test specification Additional specifications For more information about your server, such as memory size, hard drive size, and processor type, visit Gateway's eSupport page at support.gateway.com. The eSupport page also has links to additional Gateway documentation and detailed specifications for your server. 82 www.gateway.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

82
www.gateway.com
Environmental specifications
The following specifications identify maximum environmental conditions. At no time
should the server run under conditions which violate these specifications.
Additional specifications
For more information about your server, such as memory size, hard drive size, and
processor type, visit Gateway’s
eSupport
page at
support.gateway.com
. The
eSupport
page
also has links to additional Gateway documentation and detailed specifications for your
server.
Variable
Requirements
Temperature
Operating: 41° to 95°F (5° to 35°C) Maximum rate of change: 18°F
(10°C) per hour
Non-operating: -40° to 158°F (-40° to 70°C)
Humidity
Non-operating: 95% relative (non-condensing) at 80° F (30° C)
Operating shock
No errors with a half sine wave shock of @ G (with 11 millisecond
duration)
Package shock
Operations after a 30-inch (76.2-cm) fall. Cosmetic damage may be
present (chassis weight 30 lbs/13.6 kg)
ESD
+/- 15 kV per Intel environmental test specification