L LOCATION 37 - SIREN AND SYSTEM SUPERVISION (5 segments, feature selection data) Location 37 is used to enable various system feature and reporting options. (Refer to the feature definitions.) Segment 1: 1 - On if siren sounds for "Telephone Line Cut" when armed. 2 - On if siren sounds for "Telephone Line Cut" when disarmed. 3 - On if siren blast at arming. 4 - On if siren blast at exit expiration. 5 - On if siren blast at closing kissoff. 6 - On if siren sounds during a "Cross Zone" verification time. 7 - On if siren sounds for a Zone or Box Tamper. 8 - On if siren blasts 1 time for keyswitch or wireless arming; 2 times for disarming. Segment 2: 1 - On if siren driver should be a voltage output. Off if on board siren driver enabled. 2 - On if siren sounds for expander trouble (required for UL installations). 3 - On for Immediate Restore by zone. Off for zones to restore only when siren is off. 4 - On if Dynamic Battery Test performed at arming. Off if performed at disarming. (See location 40) 5 - On if Battery Missing Test is performed every 12 seconds. 6 - On if Manual Bell Test performed during [r]-[4] test function. 7 - On if Manual Communicator Test performed during [r]- [4] test function. 8 - On if Box Tamper terminals on the control panel are enabled. Segment 3: 1 - On if Box Tamper report enabled. 2 - On if AC Fail reporting enabled. 3 - On if Low Battery reporting enabled. 4 - On if Aux. Power Overcurrent report enabled. 5 - On if Siren Supervision report enabled. 6 - On if Telephone Line Cut report enabled. 7 - On if Ground Fault Detection report enabled. 8 - On if Expander Trouble reporting enabled. Segment 4: 1 - On if Fail To Communicate report enabled. 2 - On if Log Full report enabled. 3 - On if Autotest report enabled. 4 - On if Start/End programming report enabled. 5 - On if End Download report enabled. 6 - On if Sensor Low Battery report enabled. 7 - On if Sensor Missing report enabled. 8 - Reserved. Segment 5: 1 = On enable Lost Clock service light. 2 = On enables Zone Doubling (requires NX-200 Zone Doubling Kit). 3 = On disables On-Board 8 zones. 4 = On will allow two trips on same cross-zone to activate an alarm. 5 = On will not allow zones that are force armed to report bypass. 6 = On enables Silent Exit option. 7 = Use internal crystal for clock. 8 = Disable Temporal Siren on Fire. NOTE: Do NOT disable for UL listed systems. L LOCATION 38 - SWINGER SHUTDOWN COUNT Location 38 contains the number of trips during an arming cycle that the NX8 will allow before bypassing a zone. The count determination is described in the feature definitions beginning on page 3. NOTE: For UL installations, this feature shall be disabled. . L LOCATION 39 - KEYPAD SOUNDER CONTROL (1 segment, feature selection data) Segment 1: 1 - On if keypad sounds for ATelephone Line Cut@ when the system is armed. 2 - On if keypad sounds for ATelephone Line Cut@ when disarmed. 3 - On if keypad sounds upon AC Power Failure. 4 - On if keypad sounds when a Low Battery is detected. 5 - On if keypad sounds during Cross Zone trip time. 6 - On if keypad sounds for zone and box tampers. 7 - Reserved. 8 - On if keypad sounds for expander trouble (required for UL installations). Page 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

Page 21
L
LOCATION 37 - SIREN AND SYSTEM SUPERVISION
(5 segments, feature selection data)
Location 37 is used to enable various system feature and reporting options. (Refer to the feature definitions.)
Segment 1:
1 - On if siren sounds for "Telephone Line Cut" when armed.
2 - On if siren sounds for "Telephone Line Cut" when disarmed.
3 - On if siren blast at arming.
4 - On if siren blast at exit expiration.
5 - On if siren blast at closing kissoff.
6 - On if siren sounds during a "Cross Zone" verification time.
7 - On if siren sounds for a Zone or Box Tamper.
8 - On if siren blasts 1 time for keyswitch or wireless arming; 2 times for disarming.
Segment 2:
1 - On if siren driver should be a voltage output. Off if on board siren driver enabled.
2 - On if siren sounds for expander trouble (required for UL installations).
3 - On for Immediate Restore by zone. Off for zones to restore only when siren is off.
4 - On if Dynamic Battery Test performed at arming. Off if performed at disarming. (See location 40)
5 - On if Battery Missing Test is performed every 12 seconds.
6 - On if Manual Bell Test performed during [
r
]-[4] test function.
7 - On if Manual Communicator Test performed during [
r
]- [4] test function.
8 - On if Box Tamper terminals on the control panel are enabled.
Segment 3:
1 - On if Box Tamper report enabled.
2 - On if AC Fail reporting enabled.
3 - On if Low Battery reporting enabled.
4 - On if Aux. Power Overcurrent report enabled.
5 - On if Siren Supervision report enabled.
6 - On if Telephone Line Cut report enabled.
7 - On if Ground Fault Detection report enabled.
8 - On if Expander Trouble reporting enabled.
Segment 4:
1 - On if Fail To Communicate report enabled.
2 - On if Log Full report enabled.
3 - On if Autotest report enabled.
4 - On if Start/End programming report enabled.
5 - On if End Download report enabled.
6 - On if Sensor Low Battery report enabled.
7 - On if Sensor Missing report enabled.
8 - Reserved.
Segment 5:
1 = On enable Lost Clock service light.
2 = On enables Zone Doubling (requires NX-200 Zone Doubling Kit).
3 = On disables On-Board 8 zones.
4 = On will allow two trips on same cross-zone to activate an alarm.
5 = On will
not
allow zones that are force armed to report bypass.
6 = On enables Silent Exit option.
7 = Use internal crystal for clock.
8 = Disable Temporal Siren on Fire.
NOTE: Do NOT disable for UL listed systems
.
L
LOCATION 38 - SWINGER SHUTDOWN COUNT
Location 38 contains the number of trips during an arming cycle that the NX8 will allow before bypassing a zone. The
count determination is described in the feature definitions beginning on page 3.
NOTE: For UL installations, this
feature shall be disabled.
.
L
LOCATION 39 - KEYPAD SOUNDER CONTROL (1 segment, feature selection data)
Segment 1:
1 - On if keypad sounds for
A
Telephone Line Cut
@
when the system is armed.
2 - On if keypad sounds for
A
Telephone Line Cut
@
when disarmed.
3 - On if keypad sounds upon AC Power Failure.
4 - On if keypad sounds when a Low Battery is detected.
5 - On if keypad sounds during Cross Zone trip time.
6 - On if keypad sounds for zone and box tampers.
7 - Reserved.
8 - On if keypad sounds for expander trouble (required for UL installations).