GE NX-8 Installation Manual - Page 49

The Defaults Listed In The Odd Numbered Locations Below Represent The Three Segments

Page 49 highlights

LOC PG DESCRIPTION DEFAULT DATA 108 32 PARTITION 8, FEATURE AND REPORTING SELECTION Segment #1 Segment #2 Segment #3 1 Quick Arm 1 LED Extinguish enable 1 Open/Close 2 Re-Exit 2 Require user code for bypassing zones 2 Bypass 3 Auto Bypass 3 Bypass sounder alert 3 Restore 4 Silent Panic 4 AC Power/Low Battery sounder alert 4 Trouble 5 Audible Panic 5 Enables Bypass toggle 5 Tamper 6 Auxiliary 1 6 Enables Silent Auto Arm 6 Cancel 7 Auxiliary 2 7 Enables Automatic Instant 7 Recent Closing 8 Multi Keypress Tamper 8 Reserved 8 Exit Error 109 33 PARTITION 8, ENTRY/EXIT TIMERS Segment #1 (Entry Time #1) 0 _ Segment #2 (Exit Time #1) 0 _ Segment #3 (Entry Time #2) 0 _ Segment #4 (Exit Time #2) 0 _ 110 33 ZONE TYPE 1 ALARM EVENT CODE 8 _ 111 33 ZONE TYPE 1 CHARACTERISTIC SELECT Segment #1 (Circle numbers to program) 1 Fire (enable for fire zone). 5 Delay 1 zone (enable to follow Timer 1 Entry/Exit 2 24 Hour (enable for non-fire 24 hour times). zone). 6 Delay 2 zone (enable to follow Timer 2 Entry / Exit 3 Keyswitch zone. times). 4 Follower (enable for burg zones that are 7 Interior (Enable for auto bypass or stay arming). instant during non-entry times). 8 Local Only (enable if zone is not to be reported). Segment #2 (Circle numbers to program) 1 Keypad audible on alarm. 5 Bypassable. 2 Yelping siren on alarm. 3 Temporal siren on alarm. 4 Chime. 6 Group Shunt. 7 Force armable. 8 Entry Guard. Segment #3 (Circle numbers to program) 1 Fast Loop Response. 5 Dialer Delay zone. 2 Double End of Line Tamper zone. 6 Swinger zone. 3 Trouble zone (Day zone). 4 Cross Zone. 7 Restore reporting. 8 Listen-In. THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM LOCATION 111 TO UNDERSTAND THESE DEFAULTS. 112 33 ZONE TYPE 2 ALARM EVENT CODE 113 33 ZONE TYPE 2 CHARACTERISTIC SELECT 114 33 ZONE TYPE 3 ALARM EVENT CODE 115 34 ZONE TYPE 3 CHARACTERISTIC SELECT 116 34 ZONE TYPE 4 ALARM EVENT CODE 117 34 ZONE TYPE 4 CHARACTERISTIC SELECT 118 34 ZONE TYPE 5 ALARM EVENT CODE 119 34 ZONE TYPE 5 CHARACTERISTIC SELECT 120 34 ZONE TYPE 6 ALARM EVENT CODE 121 34 ZONE TYPE 6 CHARACTERISTIC SELECT 122 34 ZONE TYPE 7 ALARM EVENT CODE 123 34 ZONE TYPE 7 CHARACTERISTIC SELECT 124 34 ZONE TYPE 8 ALARM EVENT CODE 2 _ 2-125-78 7 _ 5-1245-5678 5 _ 45-125-5678 5 _ 457-125-5678 4 _ 0-1245-5678 0 _ 2-0-78 1 _ Page 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

Page 49
LOC
PG
DESCRIPTION
DEFAULT
DATA
PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1
Segment #2
Segment #3
108
32
1
2
3
4
5
6
7
8
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
1
2
3
4
5
6
7
8
LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved
1
2
3
4
5
6
7
8
Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error
109
33
PARTITION 8, ENTRY/EXIT TIMERS
Segment #1
(Entry Time #1)
0
_
Segment #2
(Exit Time #1)
0
_
Segment #3
(Entry Time #2)
0
_
Segment #4
(Exit Time #2)
0
_
110
33
ZONE TYPE 1 ALARM EVENT CODE
8
_
111
33
ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1
(Circle numbers to program)
1
2
3
4
Fire (enable for fire zone).
24 Hour (enable for non-fire 24 hour
zone).
Keyswitch zone.
Follower (enable for burg zones that are
instant during non-entry times).
5
6
7
8
Delay 1 zone (enable to follow Timer 1 Entry/Exit
times).
Delay 2 zone (enable to follow Timer 2 Entry / Exit
times).
Interior (Enable for auto bypass or stay arming).
Local Only (enable if zone is not to be reported).
Segment #2
(Circle numbers to program)
1
2
3
4
Keypad audible on alarm.
Yelping siren on alarm.
Temporal siren on alarm.
Chime.
5
6
7
8
Bypassable.
Group Shunt.
Force armable.
Entry Guard.
Segment #3
(Circle numbers to program)
1
2
3
4
Fast Loop Response.
Double End of Line Tamper zone.
Trouble zone (Day zone).
Cross Zone.
5
6
7
8
Dialer Delay zone.
Swinger zone.
Restore reporting.
Listen-In.
THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF
EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM LOCATION 111 TO UNDERSTAND
THESE DEFAULTS.
112
33
ZONE TYPE 2 ALARM EVENT CODE
2
_
113
33
ZONE TYPE 2 CHARACTERISTIC SELECT
2-125-78
114
33
ZONE TYPE 3 ALARM EVENT CODE
7
_
115
34
ZONE TYPE 3 CHARACTERISTIC SELECT
5-1245-5678
116
34
ZONE TYPE 4 ALARM EVENT CODE
5
_
117
34
ZONE TYPE 4 CHARACTERISTIC SELECT
45-125-5678
118
34
ZONE TYPE 5 ALARM EVENT CODE
5
_
119
34
ZONE TYPE 5 CHARACTERISTIC SELECT
457-125-5678
120
34
ZONE TYPE 6 ALARM EVENT CODE
4
_
121
34
ZONE TYPE 6 CHARACTERISTIC SELECT
0-1245-5678
122
34
ZONE TYPE 7 ALARM EVENT CODE
0
_
123
34
ZONE TYPE 7 CHARACTERISTIC SELECT
2-0-78
124
34
ZONE TYPE 8 ALARM EVENT CODE
1
_