GE NX-8 Installation Manual - Page 43
Enables Go To Program Code for partition #8. - master code
UPC - 782136401462
View all GE NX-8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
LOC PG DESCRIPTION DEFAULT DATA 43 22 GO TO PROGRAM CODE PARTITION AND AUTHORIZATION Segment #1 (Circle numbers to program) 1 Reserved. 2 Enables "Go To Program Code" as an arm only code. 3 Enables "Go To Program Code" as an arm only after closing. 4 Enables "Go To Program Code" as a master arm/disarm code (can change user codes) 5 Enables "Go To Program Code" as an arm/disarm code. 6 Enables "Go To Program Code" to bypass zones. 7 Enables "Go To Program Code" opening and closing reports. 8 Reserved. Segment #2 (Circle numbers to program) 1 Enables "Go To Program Code" for partition #1. 2 Enables "Go To Program Code" for partition #2. 3 Enables "Go To Program Code" for partition #3. 4 Enables "Go To Program Code" for partition #4. 5 Enables "Go To Program Code" for partition #5. 6 Enables "Go To Program Code" for partition #6. 7 Enables "Go To Program Code" for partition #7. 8 Enables "Go To Program Code" for partition #8. L 44 23 DURESS CODE 15-15-15-15-15-15 45 23 AUXILIARY OUTPUTS 1-4 PARTITION SELECTION Segments 1 2 3 4 Partition #1 1 1 1 1 Partition #2 2 2 2 2 Partition #3 3 3 3 3 Partition #4 4 4 4 4 Partition #5 5 5 5 5 Partition #6 6 6 6 6 Partition #7 7 7 7 7 Partition #8 8 8 8 8 46 23 AUXILIARY OUTPUTS 1-4 SPECIAL TIMING Segments 1 2 Auxiliary output timed in minutes. 1 1 Auxiliary output to latch. 2 2 Auxiliary output to stop timing upon user code entry. 3 3 Auxiliary output to activate only between closing and opening time. 4 4 Auxiliary output to activate only between opening and closing time. 5 5 Invert auxiliary output ( 0 volts going to 12 volts when activated). 6 6 Reserved 7 7 Reserved 8 8 47 23 AUXILIARY OUTPUT #1, EVENT & TIME Segment #1: Program the event number for output #1 here. Segment #2: Program the timing for output #1 here . 48 23 AUXILIARY OUTPUT #2, EVENT & TIME Segment #1: Program the event number for output #2 here. Segment #2: Program the timing for output #2 here . 49 23 AUXILIARY OUTPUT #3, EVENT & TIME Segment #1: Program the event number for output #3 here. Segment #2: Program the timing for output #3 here . 50 23 AUXILIARY OUTPUT #4, EVENT & TIME Segment #1: Program the event number for output #4 here. Segment #2: Program the timing for output #4 here . 0=Burglary alarm 10 seconds 1=Fire alarm 10 seconds 2= 24 Hour Alarm 10 seconds 21-Armed State 0=Follow condition ______ 3 4 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 Page 43