E: Capacity compensation value at different piping length and drop AV08NMVERA liquid pipe:φ12.7 AV10NMVERA 1.00 gas pipe:φ22.22 1.00 liquid pipe:φ12.7 gas pipe:φ22.22 cooling compensation factor cooling compensation factor 0.95 0.95 0.90 0.85 liquid pipe:φ9.52 gas pipe:φ19.05 0.80 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) 0.90 liquid pipe:φ9.52 0.85 gas pipe:φ22.22 0.80 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) cooling compensation factor AV12NMVERA 1.00 0.95 0.90 liquid pipe:φ12.7 gas pipe:φ28.58 0.85 0.80 liquid pipe:φ12.7 gas pipe:φ25.4 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) 1.00 AV16NMVERA liquid pipe:φ12.7 gas pipe:φ31.8 0.95 0.90 0.85 0.80 0 liquid pipe:φ12.7 gas pipe:φ28.58 20 40 60 80 100 120 140 160 180 pipe length of single way (m) cooling compensation factor cooling compensation factor 1.00 AV14NMVERA liquid pipe:φ12.7 gas pipe:φ28.58 0.95 0.90 0.85 liquid pipe:φ12.7 gas pipe:φ25.4 0.80 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) 1.00 AV18NMVERA 0.95 0.90 0.85 liquid pipe:φ15.88 gas pipe:φ28.58 0.80 liquid pipe:φ15.88 gas pipe:φ31.8 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) cooling compensation factor cooling compensation factor G R U P A d.o.o. cooling compensation factor 1.00 AV20NMVERA 0.95 0.90 0.85 liquid pipe:φ15.88 gas pipe:φ28.58 liquid pipe:φ15.88 gas pipe:φ31.8 0.80 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) cooling compensation factor 1.00 0.95 AV22NMVERA liquid pipe:φ15.88 gas pipe:φ31.8 0.90 0.85 liquid pipe:φ15.88 gas pipe:φ28.58 0.80 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) 1.00 AV24NMVERA liquid pipe:φ15.88 gas pipe:φ31.8 0.95 0.90 0.85 liquid pipe:φ15.88 0.80 gas pipe:φ28.58 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) cooling compensation factor AV26NMVERA 1.00 0.95 0.90 0.85 0.80 0 liquid pipe:φ19.05 gas pipe:φ31.8 liquid pipe:φ19.05 gas pipe:φ38.1 20 40 60 80 100 120 140 160 180 pipe length of single way (m) cooling compensation factor 1.00 0.95 AV28NMVERA 1.00 0.95 AV30NMVERA liquid pipe:φ19.05 gas pipe:φ38.1 0.90 0.85 0.80 liquid pipe:φ19.05 gas pipe:φ31.8 liquid pipe:φ19.05 gas pipe:φ38.1 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) 0.90 0.85 liquid pipe:φ19.05 gas pipe:φ31.8 0.80 0 20 40 60 80 100 120 140 160 180 pipe length of single way (m) 85 cooling compensation factor