Haier AV16NMVERA Design Manual - Page 93
»ÅÑÍÓæÏï, Á×À², »ÅÑÍÓæÏ
View all Haier AV16NMVERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
Remarks: A. Charging amount when out of factory excludes the refrigerant in the pipe. B . Additional charging amount=actual length of liquid pipe*additional amount per meter liquid pipe Additional charging amount=L1*0.35+L2*0.25+L3*0.17+L4*0.11+L5*0.054+L6*0.022 L1: total length of 22.22 liquid pipe L2: total length of 19.05 liquid pipe L3: total length of 15.88 liquid pipe L4: total length of 12.7 liquid pipe L5: total length of 9.52 liquid pipe L6:total length of 6.35 liquid pipe 6. Requestment of copper pipe specs and thickness Exterior diameter(mm) Pipe thickness(mm) Remarks 6.35 more than 0.8 9.52 more than 0.8 12.7 more than 1.0 coil pipe 15.88 19.05 more than 1.0 more than 1.0(straight pipe) more than 1.0 (coil pipe) 22.22 more than 1.0 25.4 more than 1.0 28.58 31.8 more than 1.0 more than 1.1 straight pipe 34.9 more than 1.3 38.1 more than 1.4 41.8 more than 1.5 G R U P A d.o.o. 93