HP 1606 HP StorageWorks Fabric OS 6.3.1c Release Notes (5697-0509 September 2 - Page 48
After changing FID on HP StorageWorks 8/40 SAN Switch and then, HA cluster member node
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
With McDATA default zone enabled, when numerous NPIV devices in the default zone come online at the same time, some devices were missing from the portcam table. Fixed in Fabric OS 6.3.0 Workaround prior to code change: This is due to multiple devices logging in simultaneously. So apply portdisable to all ports connected to the devices and apply portenable sequentially. This will resolve the issue. NPIV devices in Interopmode 2 default zone is not supported. NPIV devices should be part of the active zone configuration. Fabric mode TT does not show all the flows when device port is disabled and enabled back after TT monitor installation. Fixed in Fabric OS 6.3.0 If using WebTools to perform cfgsaveactivetodefined with a zone file close to the maximum size in an interop mode fabric with more than 20 switches, the weblinker process may get terminated. Fixed in Fabric OS 6.3.0 In a mixed fabric of VF enabled and non-VF switches, a VF enabled switch may not be able to detect the FID conflict with the other VF enabled switch, if there are non-VF switches in the path interconnecting the VF enabled switches. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Follow the raslog errors FABR-1044 or FABR-1043 displayed by switches in the fabric to identify the offending switch and resolve the FID conflict. IPC message from module CALD to Management Server is dropped Fixed in Fabric OS 6.3.0 by Management server. This causes CALD module to wait indefinitely. Sometimes config file downloaded may cause the configdownload command to crash. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Disable the switch and then attempt configdownload. After changing FID on HP StorageWorks 8/40 SAN Switch and then performing switchenable, switchdisable, observed ASSERT. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Do not disable a switch immediately after enabling if it's coming up with a new FID for the first time. Wait for at least 10 seconds before issuing switchdisable. HA cluster member node, HP StorageWorks Encryption SAN Switch Fixed in Fabric OS 6.3.0 faults as a result of slot power cycling its HA cluster peer (HP Storage- Workaround prior to code change: Works DC Encryption FC Blade). Reboot the Encryption SAN Switch. IPL file is not getting updated, when a PDCM matrix is activated using Fixed in Fabric OS 6.3.0 WebTools with Active=Save Mode checked. Fabric Watch failed to initialize on fully populated HP StorageWorks Fixed in Fabric OS 6.3.0 DC SAN Backbone Director. Memory leak when querying connUnitPortFCId in Access Gateway (AG) mode and also when querying FcFeModuleName. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Avoid querying FcFeModuleName or (connUnitPortFCId in AG mode) MIB to avoid memory leak. 48