HP 1606 HP StorageWorks Fabric OS 6.3.1c Release Notes (5697-0509 September 2 - Page 62
Close and re-open Fabric Watch., DC SAN Director
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Enabled minimum Fabric OS support for DWDM-SFP port media. Fixed in Fabric OS 6.3.0 Re-keys are getting stuck. Fixed in Fabric OS 6.3.0 DC SAN Director: configdownload: simple upload/download (switch enabled) complaining about FID 128 and will not download with switch enabled. Fixed in Fabric OS 6.3.0 Switch Admin: CEE: NPE is shown in error message when user applies a new FCoE login group (with Login management disabled.) Fixed in Fabric OS 6.3.0 Workaround prior to code change: User has to execute the CLI command fcoelogincfg before using WebTools to create the login groups. pertperfshow does not display decimal data if overall throughput Fixed in Fabric OS 6.3.0 exceeds 10Gbps. A switch restart causes random ICL E-Ports to come up "segmented." Fixed in Fabric OS 6.3.0 Workaround prior to code change: Port toggle when it gets segmented. When running FCoE traffic, debug_csock_read_header failures mes- Fixed in Fabric OS 6.3.0 sage displays. Fabric Watch: The FRU status does not auto-refresh after removal/insertion of the FRU. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Close and re-open Fabric Watch. FCoE frames from any SMAC are incorrectly passed to the FC side. Switchname mismatch between GUI display and CLI. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Issues with Brocade MIB objects with ifSpeed returns wrong value, ifOutUcastPkts, ipAdEntReasmMaxSize, ipRouteAge, ipRoutingDiscards, Fixed in Fabric OS 6.3.0 snmpSilentDrops, snmpProxyDrops needs to be documented. After cfgdefault and migration from Interopmode 0 to Interopmode 2, all switches are setting idid bit in ESA, when idid is not enabled. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Fabric can be merged by disabling the switches and setting idid mode in the switch configurations, then bringing the switches online. This option is applicable only in the event the user wishes to merge the switch to a fabric that also has idid set. Syshutdown: execution of command in current build yields only "this Fixed in Fabric OS 6.3.0 is a unknown system" string on session consoles. Cannot use fwconfigure to view the information on internal F/FL ports (Copper). Fixed in Fabric OS 6.3.0 Internal routes are not being configured. Fixed in Fabric OS 6.3.0 Port state mismatch on internal copper ports on Embedded platforms Fixed in Fabric OS 6.3.0 between switchshow and portcfgshow's PersistentDisable flag. 62