HP 1606 HP StorageWorks Fabric OS 6.3.1c Release Notes (5697-0509 September 2 - Page 60
Fixed in Fabric OS 6.3.0, the 2408 FCoE CN Switch.
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
"Enable Inactive port" tab in the EZmanager has to be disabled for the 2408 FCoE CN Switch. Fixed in Fabric OS 6.3.0 8/8 or 8/16 SAN Switch not responding to Link Reset primitives cor- Fixed in Fabric OS 6.3.0 rectly. When a trunk master port is disabled, fabric watch incorrectly sets the new trunk master's health to offline, and remote side to faulty even though port is online. Fixed in Fabric OS 6.3.0 Workaround prior to code change: New master incorrectly reported as offline or faulty after trunk master disable. No workaround, hafailover can be used as recovery. CAL Response for Brocade_ISL CAL class is returning wrong port information in case of Edge to Backbone Device Sharing (when TD is available in FCR fabric). Fixed in Fabric OS 6.3.0 Console is not accessible on 8GB SAN Switch for HP BladeSystem c- Fixed in Fabric OS 6.3.0 Class. Blade fault observed with a 4/256 SAN Director chassis fully loaded Fixed in Fabric OS 6.3.0 with 8Gb 48-port blades. Deleted offline/inactive device using zone validate window in EZman- Fixed in Fabric OS 6.3.0 ager is not replicated in CLI. Encryption SAN Switch and Encryption FC blade do not support en- Fixed in Fabric OS 6.3.0 crypted LUNs >2TB. Switch Admin: Proper error message should pop up when disabling of FCoE in a VLAN fails. Fixed in Fabric OS 6.3.0 Workaround prior to code change: View the switch events to determine the reason for failure. Switch panic when supportsave read invalid data on GE ports without Fixed in Fabric OS 6.3.0 FC Fastwrite enabled. Firmware downgrade from Fabric OS 6.2.0 to 6.1.0 sometimes causes an unresponsive console, which requires a switch power cycle to recover. Fixed in Fabric OS 6.3.0 Workaround prior to code change: 1. Avoid using firmwaredownload -sb i.e. avoid auto-reboot. Use firmwaredownload -s and then do a manual reboot. 2. Need to power cycle the switch. The switch functions properly after power cycle with normal access to the telnet session. Rekeyed LUNs are in "Not Ready (Getting key from archive)" state when the key vault goes down and does not recover. WebTools Zone Admin "Add member" button is always disabled. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Workaround prior to code change: Add members with the "Add other" button. In non-VF mode on DC SAN Director, after removing other filters (EE and F_Port TT) and enabling Fabric mode TopTalkers, the flow values are not reliable. Fixed in Fabric OS 6.3.0 60