HP 1606 HP StorageWorks Fabric OS 6.3.1c Release Notes (5697-0509 September 2 - Page 56

On some of 2408 FCoE Converged Network switches, DIAGPOST is

Page 56 highlights

FICON XRC Emulation error handling OOO Status Frames. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Option 1: Deactivate all paths that utilize the same device ports and reactivate at the same time. Option 2: Disable FICON XRC emulation. HIL-1610 WARNING appeared on 8/40 switch units after power cycle. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Ignore the warning - it is innocuous when seen right at boot up time. It results from a solitary spurious sensor reading that is below minimum. Temperature sensor reporting spurious solitary readings which leads to the CRITICAL HIL-1502 message, without having first gone through the HIL-1501 warning. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Ignore isolated / spurious High Temperature CRITICAL errors when not preceded by warnings. Unable to get F Ports(Trunk Ports) data. Fixed in Fabric OS 6.3.0 On some of 2408 FCoE Converged Network switches, DIAGPOST is Fixed in Fabric OS 6.3.0 failing due to loss of sync. Processor rebooted - Software Fault:ASSERT when frame size received Fixed in Fabric OS 6.3.0 is too big. Need to support a command "clear logging" to clear all debug log messages accumulated. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Go to FOS mode and issue an errclear command. CLI output consistency and input validation issues around key lifespan option of a LUN. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Input validation issues. Requires the user to provide valid input. High Availability : User is able to change the "desired distance" for long distance "L0". User should not be able to change the "Desired distance" if the "Long distance" value is "L0". It should always be "N/A" for L0. Fixed in Fabric OS 6.3.0 After firmware upgrade, FC FastWrite traffic sometimes fails. Fixed in Fabric OS 6.3.0 A few VERIFYs are dumped out on DC SAN Director and Multiprotocol Router Blade EX port stuck without showing switch name of the edge Fixed in Fabric OS 6.3.0 fabric switch etc during edge switch firmwareupgrade. FMS mode should be blocked when a logical switch is in 10 bit ad- Fixed in Fabric OS 6.3.0 dressing. TI Zone activation failed when pushing from DCFM to fabric with 6.2.0 Fixed in Fabric OS 6.3.0 and 6.1.2. The drive is taken offline after container is failed back. Fixed in Fabric OS 6.3.0 56

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Option 1: Deactivate all paths that
utilize the same device ports and
reactivate at the same time. Option
2: Disable FICON XRC emulation.
FICON XRC Emulation error handling OOO Status Frames.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Ignore the warning - it is innocuous
when seen right at boot up time. It
results from a solitary spurious sensor
reading that is below minimum.
HIL-1610 WARNING appeared on 8/40 switch units after power
cycle.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Ignore isolated / spurious High
Temperature CRITICAL errors when
not preceded by warnings.
Temperature sensor reporting spurious solitary readings which leads
to the CRITICAL HIL-1502 message, without having first gone through
the HIL-1501 warning.
Fixed in Fabric OS 6.3.0
Unable to get F Ports(Trunk Ports) data.
Fixed in Fabric OS 6.3.0
On some of 2408 FCoE Converged Network switches, DIAGPOST is
failing due to loss of sync.
Fixed in Fabric OS 6.3.0
Processor rebooted - Software Fault:ASSERT when frame size received
is too big.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Go to FOS mode and issue an
errclear
command.
Need to support a command "clear logging" to clear all debug log
messages accumulated.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Input validation issues. Requires the
user to provide valid input.
CLI output consistency and input validation issues around key lifespan
option of a LUN.
Fixed in Fabric OS 6.3.0
High Availability : User is able to change the "desired distance" for
long distance "L0". User should not be able to change the "Desired
distance" if the "Long distance" value is "L0". It should always be
"N/A" for L0.
Fixed in Fabric OS 6.3.0
After firmware upgrade, FC FastWrite traffic sometimes fails.
Fixed in Fabric OS 6.3.0
A few VERIFYs are dumped out on DC SAN Director and Multiprotocol
Router Blade EX port stuck without showing switch name of the edge
fabric switch etc during edge switch
firmwareupgrade
.
Fixed in Fabric OS 6.3.0
FMS mode should be blocked when a logical switch is in 10 bit ad-
dressing.
Fixed in Fabric OS 6.3.0
TI Zone activation failed when pushing from DCFM to fabric with 6.2.0
and 6.1.2.
Fixed in Fabric OS 6.3.0
The drive is taken offline after container is failed back.
56