HP 4400 HP B-series Fabric OS 7.0.0a Release Notes (5697-0881, June 2011) - Page 29
Encryption Behavior for the HP StorageWorks Encryption SAN Switch and HP StorageWorks - drivers
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Access Gateway device-based mapping in ESX environments Users who want to utilize Access Gateway's Device-based mapping feature in the ESX environments should refer to the Brocade Tech Note Using Brocade Access Gateway Device-Based Mapping in VMware ESX Server Environments for best implementation practices. This document can be downloaded from the following HP website: http://www.hp.com/support/manuals Under storage, select Storage networking, and then select the appropriate switch under B-series Switches. Brocade HBA/Adapter Compatibility Brocade HBA/Adapter should be using driver version 2.3.0.2 or later when attached to 16 Gbps ports on Brocade switches. D_Port • Fabric OS 7.0.0a supports the execution of D_Port tests concurrently on up to eight ports on the switch. • D_Port tests may be executed only on ports configured for portcfglongdistance port# L0 or normal port distance mode. Executing D_Port tests on long distance ports may cause tests to fail due to time out exceeded. NOTE: The following message appears in CLI when Enabling D_Port with HP B-series SFPs Caution: D_Port functionality is only available on 16G-capable platforms with Brocade branded 16G SFPs and 10G FC SFPs. Electrical and Optical loopback tests are supported only for Brocade branded 16G SFPs. Although this message appears, D_Port functions as expected with the HP B-series SFPs installed. This error message will be removed in a subsequent Fabric OS release. • There is no D_Port capability for 10 Gbps links nor for the 16 Gbps fabric at the far end of the 10 Gbps link. Encryption Behavior for the HP StorageWorks Encryption SAN Switch and HP StorageWorks DC Switch Encryption FC Blade • When doing a firmware upgrade to Fabric OS 7.0.0a or downgrade from Fabric OS 7.0.0a, message SPM-1016 is issued on nodes in the EG (Encryption Group) when there are other nodes in that EG that are still running pre-Fabric OS 7.0.0a. Although this is a warning message, it is transient and is observed only during a firmware upgrade or downgrade operation and can be ignored. The message text is: 2011/04/12-18:41:08, [SPM-1016], 17132, FID 128, WARNING, pt1b-tw-102, Security database is out of sync. This warning can be ignored if the nodes in the EG are running different versions of FOS. HP B-series Fabric OS 7.0.0a Release Notes 29