Closed fixes summary There is no column for discard_C3_timeout_only in porterrshow. Solution Workaround prior to upgrade:Users should use the portstatsshow CLI to find the c3 Rx and Tx timeout discards as the porterrshow CLI will only show the summation of many c3 discards. Fixed in Fabric OS 7.0.0. The Port Admin window indicates Online/Healthy, yet additional port Info indicates the port is segmented. Fixed in Fabric OS 7.0.0. In a FICON environment, FICON CUP cannot be enabled when a faulted blade exists in the chassis. Fixed in Fabric OS 7.0.0. After enabling https, a failover will cause the active CP to still be running http and users will not have https services after a failover. Workaround prior to upgrade:Issue another HA Failover to cause both CPs to reset the web services. Fixed in Fabric OS 7.0.0. In Access Gateway mode, devices with QoS enabled on HBA and F_Port and N_Port would intermittently come online without the AoQ bit set. Fixed in Fabric OS 7.0.0. Removal of the HP StorageWorks B-Series Multi-protocol Router Blade or the HP DC SAN Director 10/24 FCoE Blade could crash the HP Fixed in Fabric OS 7.0.0. StorageWorks DC SAN Backbone Director Switch during POST. FAN frames are not being sent by the switch to loop devices after LIP when fcAL.fanFrameDisable is set to 0. Fixed in Fabric OS 7.0.0. The HP 2408 FCoE Switch and HP DC SAN Director 10/24 FCoE Blade ignore initial discovery solicitations from the CNA and go into pre-FIP mode when spanning tree is enabled. Workaround prior to upgrade:Disable the spanning tree or configure the interface as "spanning-tree edgeport". Fixed in Fabric OS 7.0.0. RASLOG message SCN-1001 severity may be misleading. Fixed in Fabric OS 7.0.0. In a FICON environment, the HP StorageWorks DC SAN Backbone Director Switch portstatsshow indicates a different value than RMF is reading through the CUP using CMD= 32 (Read port statistics). Even though the counters are updated in both cases, different values are returned for each interface. Fixed in Fabric OS 7.0.0. There are inconsistencies between WebTools and the CLI; WebTools do not show configured slots for expired trial trial slot-based licenses, but the CLI does. Fixed in Fabric OS 7.0.0. The SNMP: IF-MIB: ifTable excludes entries of port indices greater than the port index of the Logical ISL. Users will not be able to get the ports Fixed in Fabric OS 7.0.0. that have an index greater than port index of the Logical ISL. Duplicate columns are shown in WebTools port admin advanced mode when moving between basic and advanced mode. Fixed in Fabric OS 7.0.0. Executing the configdownload command without disabling the LS switch may core dump from cfgadm. Fixed in Fabric OS 7.0.0. 50